FHWA NBI 2024 Inspection record Public-domain dataset

4152 C NS3300

Carrying 4152 C NS3300 over CREEK

.2 W .1 N OF FALLIS, Lincoln, Oklahoma

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
31 t Inventory load rating

Bridge Snapshot: 4152 C NS3300

The 4152 C NS3300 bridge in Lincoln, Oklahoma carries 4152 C NS3300 over CREEK. It was built in 1991, making it 35 years old today. The structure is built primarily of steel and spans 1 section, stretching 13.4 meters (44 feet) end to end. Daily traffic averages 575 vehicles, placing it in the lower-traffic tier of Oklahoma bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 5/9, substructure at 5/9. The weakest component sits in fair condition. All reported major components score above the Poor range. Its NBI inventory load rating is 30.8 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How 4152 C NS3300 compares

▼ 1.6
Load rating vs Oklahoma average (32.4 t)
Bottom 45%
Lower load rating than 55% of Oklahoma bridges
448
Bridges in Lincoln · 60 in Poor condition
4152 C NS3300 30.8 t
Oklahoma average 32.4 t

Live comparison across Oklahoma.

Historical Sufficiency Rating

PlainBridge-computed
74.1 / 100 - historical 50–79.9 band
Structural adequacy /55
44.3
Serviceability /30
17.8
Essentiality /15
14.9
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
30.8 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1991
Material
Steel
Number of Spans
1
Structure Length
13.4 m (44 ft)
Deck Width
7.7 m (25 ft)
Owner
County Highway Agency
Avg Daily Traffic
575 vehicles/day
Structure Number
227580000000000

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 5/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) rates fair at 5/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether 4152 C NS3300 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare 4152 C NS3300 against other structures in Lincoln and across Oklahoma. Oklahoma bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for 4152 C NS3300?

4152 C NS3300 in Lincoln, Oklahoma has a deck rating of 6/9, superstructure rating of 5/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is 4152 C NS3300 inspected?

4152 C NS3300's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 575 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. 4152 C NS3300 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for 4152 C NS3300?

4152 C NS3300 has an NBI inventory load rating of 30.8 metric tons.

Who is responsible for maintaining 4152 C NS3300?

4152 C NS3300 is owned and maintained by County Highway Agency.

How old is 4152 C NS3300 and does age affect safety?

4152 C NS3300 was built in 1991, making it 35 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.