FHWA NBI 2024 Inspection record Public-domain dataset

INTERSTATE 80 EB

Carrying INTERSTATE 80 EB over ULATIS CREEK

04-SOL-080-R26.61-VAC, Solano, California

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
19 t Inventory load rating

Bridge Snapshot: INTERSTATE 80 EB

The INTERSTATE 80 EB bridge in Solano, California carries INTERSTATE 80 EB over ULATIS CREEK. It was built in 1952, making it 74 years old today. It was last reconstructed in 1963, extending its service life. The structure is built primarily of steel and spans 5 sections, stretching 40.2 meters (132 feet) end to end. Daily traffic averages 74,500 vehicles, placing it in the heavily-trafficked tier of California bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 4/9, substructure at 7/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed. Its NBI inventory load rating is 19.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How INTERSTATE 80 EB compares

▼ 12.2
Load rating vs California average (31.3 t)
Bottom 12%
Lower load rating than 88% of California bridges
383
Bridges in Solano · 14 in Poor condition
INTERSTATE 80 EB 19.1 t
California average 31.3 t

Live comparison across California.

Historical Sufficiency Rating

PlainBridge-computed
41.0 / 100 - historical 20–49.9 band
Structural adequacy /55
14.2
Serviceability /30
22.0
Essentiality /15
4.8
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
7/9
Good (7–9)
Inventory Load Rating
19.1 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1952
Last Reconstructed
1963
Material
Steel
Number of Spans
5
Structure Length
40.2 m (132 ft)
Deck Width
20.9 m (69 ft)
Owner
State Highway Agency
Avg Daily Traffic
74,500 vehicles/day
Structure Number
23 0052R

Condition Analysis

  • The deck (driving surface) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • At 4/9, the superstructure (beams and supports above the deck) is in poor shape, with advanced wear flagged for priority repair.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

INTERSTATE 80 EB is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare INTERSTATE 80 EB against other structures in Solano and across California. California bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for INTERSTATE 80 EB?

INTERSTATE 80 EB in Solano, California has a deck rating of 5/9, superstructure rating of 4/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is INTERSTATE 80 EB inspected?

INTERSTATE 80 EB's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 74,500 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. INTERSTATE 80 EB is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for INTERSTATE 80 EB?

INTERSTATE 80 EB has an NBI inventory load rating of 19.1 metric tons.

Who is responsible for maintaining INTERSTATE 80 EB?

INTERSTATE 80 EB is owned and maintained by State Highway Agency.

How old is INTERSTATE 80 EB and does age affect safety?

INTERSTATE 80 EB was built in 1952, making it 74 years old and last reconstructed in 1963.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.