FHWA NBI 2024 Inspection record Public-domain dataset

LEWIS LANE #280

Carrying LEWIS LANE #280 over LITTLE ROCK CREEK

EAST OF CR79, Highland, Ohio

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
45 t Inventory load rating

Bridge Snapshot: LEWIS LANE #280

The LEWIS LANE #280 bridge in Highland, Ohio carries LEWIS LANE #280 over LITTLE ROCK CREEK. It was built in 2017, making it 9 years old today. The structure is built primarily of concrete and spans 1 section, stretching 15.5 meters (51 feet) end to end. Daily traffic averages 40 vehicles, placing it in the lower-traffic tier of Ohio bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 9/9, superstructure at 9/9, substructure at 9/9. The weakest component sits in good condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 45.4 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How LEWIS LANE #280 compares

▲ 7.9
Load rating vs Ohio average (37.5 t)
Top 24%
Higher load rating than 76% of Ohio bridges
245
Bridges in Highland · 5 in Poor condition
LEWIS LANE #280 45.4 t
Ohio average 37.5 t

Live comparison across Ohio.

Historical Sufficiency Rating

PlainBridge-computed
100.0 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
30.0
Essentiality /15
15.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
9/9
Good (7–9)
Superstructure
9/9
Good (7–9)
Substructure
9/9
Good (7–9)
Inventory Load Rating
45.4 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
2017
Material
Concrete
Number of Spans
1
Structure Length
15.5 m (51 ft)
Deck Width
8.5 m (28 ft)
Owner
County Highway Agency
Avg Daily Traffic
40 vehicles/day
Structure Number
3632955

Condition Analysis

  • At 9/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) rates good at 9/9, with no significant deterioration on file.
  • At 9/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether LEWIS LANE #280 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare LEWIS LANE #280 against other structures in Highland and across Ohio. Ohio bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for LEWIS LANE #280?

LEWIS LANE #280 in Highland, Ohio has a deck rating of 9/9, superstructure rating of 9/9, and substructure rating of 9/9 on the FHWA's 0–9 scale.

How often is LEWIS LANE #280 inspected?

LEWIS LANE #280's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 40 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. LEWIS LANE #280 is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for LEWIS LANE #280?

LEWIS LANE #280 has an NBI inventory load rating of 45.4 metric tons.

Who is responsible for maintaining LEWIS LANE #280?

LEWIS LANE #280 is owned and maintained by County Highway Agency.

How old is LEWIS LANE #280 and does age affect safety?

LEWIS LANE #280 was built in 2017, making it 9 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.