FHWA NBI 2024 Inspection record Public-domain dataset

W237-S85 CONNECTOR

Carrying W237-S85 CONNECTOR over STEVENS CREEK & TRAIL

04-SCL-237-R0.35-MVW, Santa Clara, California

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
37 t Inventory load rating

Bridge Snapshot: W237-S85 CONNECTOR

The W237-S85 CONNECTOR bridge in Santa Clara, California carries W237-S85 CONNECTOR over STEVENS CREEK & TRAIL. It was built in 1965, making it 61 years old today. The structure is built primarily of concrete continuous and spans 4 sections, stretching 57.3 meters (188 feet) end to end. Daily traffic averages 16,600 vehicles, placing it in the heavily-trafficked tier of California bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 37.3 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How W237-S85 CONNECTOR compares

▲ 6.0
Load rating vs California average (31.3 t)
Top 17%
Higher load rating than 83% of California bridges
1,041
Bridges in Santa Clara · 38 in Poor condition
W237-S85 CONNECTOR 37.3 t
California average 31.3 t

Live comparison across California.

Historical Sufficiency Rating

PlainBridge-computed
93.4 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
27.0
Essentiality /15
13.4
Special reductions
−2.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
37.3 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1965
Material
Concrete Continuous
Number of Spans
4
Structure Length
57.3 m (188 ft)
Deck Width
8.3 m (27 ft)
Owner
State Highway Agency
Avg Daily Traffic
16,600 vehicles/day
Structure Number
37 0200F

Condition Analysis

  • At 4/9, the deck (driving surface) is in poor shape, with advanced wear flagged for priority repair.
  • The superstructure (beams and supports above the deck) rates good at 7/9, with no significant deterioration on file.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

W237-S85 CONNECTOR is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare W237-S85 CONNECTOR against other structures in Santa Clara and across California. California bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for W237-S85 CONNECTOR?

W237-S85 CONNECTOR in Santa Clara, California has a deck rating of 4/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is W237-S85 CONNECTOR inspected?

W237-S85 CONNECTOR's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 16,600 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. W237-S85 CONNECTOR is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for W237-S85 CONNECTOR?

W237-S85 CONNECTOR has an NBI inventory load rating of 37.3 metric tons.

Who is responsible for maintaining W237-S85 CONNECTOR?

W237-S85 CONNECTOR is owned and maintained by State Highway Agency.

How old is W237-S85 CONNECTOR and does age affect safety?

W237-S85 CONNECTOR was built in 1965, making it 61 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.