FHWA NBI 2024 Inspection record Public-domain dataset

BORONDA RD

Carrying BORONDA RD over MAIN CANAL

0.3 MI N OF SH 183, Monterey, California

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
33 t Inventory load rating

Bridge Snapshot: BORONDA RD

The BORONDA RD bridge in Monterey, California carries BORONDA RD over MAIN CANAL. It was built in 1960, making it 66 years old today. The structure is built primarily of concrete continuous and spans 2 sections, stretching 14.4 meters (47 feet) end to end. Daily traffic averages 2,800 vehicles, placing it in the moderately-trafficked tier of California bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 5/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 33.0 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How BORONDA RD compares

▲ 1.7
Load rating vs California average (31.3 t)
Top 24%
Higher load rating than 76% of California bridges
390
Bridges in Monterey · 28 in Poor condition
BORONDA RD 33.0 t
California average 31.3 t

Live comparison across California.

Historical Sufficiency Rating

PlainBridge-computed
64.5 / 100 - historical 50–79.9 band
Structural adequacy /55
45.0
Serviceability /30
24.5
Essentiality /15
0.0
Special reductions
−5.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
33.0 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1960
Material
Concrete Continuous
Number of Spans
2
Structure Length
14.4 m (47 ft)
Deck Width
9.9 m (32 ft)
Owner
County Highway Agency
Avg Daily Traffic
2,800 vehicles/day
Structure Number
44C0067

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) rates fair at 5/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether BORONDA RD is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare BORONDA RD against other structures in Monterey and across California. California bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for BORONDA RD?

BORONDA RD in Monterey, California has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is BORONDA RD inspected?

BORONDA RD's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 2,800 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. BORONDA RD is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for BORONDA RD?

BORONDA RD has an NBI inventory load rating of 33.0 metric tons.

Who is responsible for maintaining BORONDA RD?

BORONDA RD is owned and maintained by County Highway Agency.

How old is BORONDA RD and does age affect safety?

BORONDA RD was built in 1960, making it 66 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.