FHWA NBI 2024 Inspection record Public-domain dataset

I10 SR8

Carrying I10 SR8 over Holmes Creek

4.0mi. East of SR79, Holmes, Florida

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
19 t Inventory load rating

Bridge Snapshot: I10 SR8

The I10 SR8 bridge in Holmes, Florida carries I10 SR8 over Holmes Creek. It was built in 1974, making it 52 years old today. The structure is built primarily of prestressed concrete and spans 15 sections, stretching 198.1 meters (650 feet) end to end. Daily traffic averages 11,500 vehicles, placing it in the heavily-trafficked tier of Florida bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 7/9, substructure at 6/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 19.3 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How I10 SR8 compares

▼ 19.6
Load rating vs Florida average (38.9 t)
Bottom 5%
Lower load rating than 95% of Florida bridges
156
Bridges in Holmes · 28 in Poor condition
I10 SR8 19.3 t
Florida average 38.9 t

Live comparison across Florida.

Historical Sufficiency Rating

PlainBridge-computed
75.1 / 100 - historical 50–79.9 band
Structural adequacy /55
39.6
Serviceability /30
28.0
Essentiality /15
7.6
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
19.3 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1974
Material
Prestressed Concrete
Number of Spans
15
Structure Length
198.1 m (650 ft)
Deck Width
13.1 m (43 ft)
Owner
State Highway Agency
Avg Daily Traffic
11,500 vehicles/day
Structure Number
520080

Condition Analysis

  • The deck (driving surface) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • At 6/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

This page shows what the last federal inspection recorded, not whether I10 SR8 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare I10 SR8 against other structures in Holmes and across Florida. Florida bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for I10 SR8?

I10 SR8 in Holmes, Florida has a deck rating of 6/9, superstructure rating of 7/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is I10 SR8 inspected?

I10 SR8's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 11,500 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. I10 SR8 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for I10 SR8?

I10 SR8 has an NBI inventory load rating of 19.3 metric tons.

Who is responsible for maintaining I10 SR8?

I10 SR8 is owned and maintained by State Highway Agency.

How old is I10 SR8 and does age affect safety?

I10 SR8 was built in 1974, making it 52 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.