FHWA NBI 2024 Inspection record Public-domain dataset

SEVENTH AVE

Carrying SEVENTH AVE over SAN JOSE CRK CHAN

0.4MI N/O SR-60 FWY, Los Angeles, California

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
41 t Inventory load rating

Bridge Snapshot: SEVENTH AVE

The SEVENTH AVE bridge in Los Angeles, California carries SEVENTH AVE over SAN JOSE CRK CHAN. It was built in 1967, making it 59 years old today. It was last reconstructed in 1978, extending its service life. The structure is built primarily of steel and spans 2 sections, stretching 54.6 meters (179 feet) end to end. Daily traffic averages 26,484 vehicles, placing it in the heavily-trafficked tier of California bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed. Its NBI inventory load rating is 41.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SEVENTH AVE compares

▲ 9.8
Load rating vs California average (31.3 t)
Top 12%
Higher load rating than 88% of California bridges
3,937
Bridges in Los Angeles · 88 in Poor condition
SEVENTH AVE 41.1 t
California average 31.3 t

Live comparison across California.

Historical Sufficiency Rating

PlainBridge-computed
89.3 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
27.0
Essentiality /15
7.3
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
41.1 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1967
Last Reconstructed
1978
Material
Steel
Number of Spans
2
Structure Length
54.6 m (179 ft)
Deck Width
29.4 m (96 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
26,484 vehicles/day
Structure Number
53C0497

Condition Analysis

  • The deck (driving surface) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

SEVENTH AVE is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare SEVENTH AVE against other structures in Los Angeles and across California. California bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SEVENTH AVE?

SEVENTH AVE in Los Angeles, California has a deck rating of 4/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is SEVENTH AVE inspected?

SEVENTH AVE's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 26,484 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SEVENTH AVE is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SEVENTH AVE?

SEVENTH AVE has an NBI inventory load rating of 41.1 metric tons.

Who is responsible for maintaining SEVENTH AVE?

SEVENTH AVE is owned and maintained by City/Municipal Highway Agency.

How old is SEVENTH AVE and does age affect safety?

SEVENTH AVE was built in 1967, making it 59 years old and last reconstructed in 1978.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.