FHWA NBI 2024 Inspection record Public-domain dataset

FORT TEJON RD

Carrying FORT TEJON RD over UNNAMED WASH

2.0MI W/O PALLET CRK RD, Los Angeles, California

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
45 t Inventory load rating

Bridge Snapshot: FORT TEJON RD

The FORT TEJON RD bridge in Los Angeles, California carries FORT TEJON RD over UNNAMED WASH. It was built in 1953, making it 73 years old today. The structure is built primarily of wood or timber and spans 1 section, stretching 7.0 meters (23 feet) end to end. Daily traffic averages 918 vehicles, placing it in the lower-traffic tier of California bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 45.4 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How FORT TEJON RD compares

▲ 14.1
Load rating vs California average (31.3 t)
Top 8%
Higher load rating than 92% of California bridges
3,937
Bridges in Los Angeles · 88 in Poor condition
FORT TEJON RD 45.4 t
California average 31.3 t

Live comparison across California.

Historical Sufficiency Rating

PlainBridge-computed
80.6 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
11.0
Essentiality /15
14.6
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
45.4 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1953
Material
Wood or Timber
Number of Spans
1
Structure Length
7.0 m (23 ft)
Deck Width
9.5 m (31 ft)
Owner
County Highway Agency
Avg Daily Traffic
918 vehicles/day
Structure Number
53C0618

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether FORT TEJON RD is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare FORT TEJON RD against other structures in Los Angeles and across California. California bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for FORT TEJON RD?

FORT TEJON RD in Los Angeles, California has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is FORT TEJON RD inspected?

FORT TEJON RD's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 918 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. FORT TEJON RD is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for FORT TEJON RD?

FORT TEJON RD has an NBI inventory load rating of 45.4 metric tons.

Who is responsible for maintaining FORT TEJON RD?

FORT TEJON RD is owned and maintained by County Highway Agency.

How old is FORT TEJON RD and does age affect safety?

FORT TEJON RD was built in 1953, making it 73 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.