FHWA NBI 2024 Inspection record Public-domain dataset

E Grant St

Carrying E Grant St over CORPORATION CANAL

E. GRANT ST., East Baton Rouge, Louisiana

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
28 t Inventory load rating

Bridge Snapshot: E Grant St

The E Grant St bridge in East Baton Rouge, Louisiana carries E Grant St over CORPORATION CANAL. It was built in 1992, making it 34 years old today. The structure is built primarily of concrete and spans 3 sections, stretching 17.4 meters (57 feet) end to end. Daily traffic averages 350 vehicles, placing it in the lower-traffic tier of Louisiana bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 27.9 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How E Grant St compares

▼ 4.4
Load rating vs Louisiana average (32.3 t)
Bottom 36%
Lower load rating than 64% of Louisiana bridges
548
Bridges in East Baton Rouge · 103 in Poor condition
E Grant St 27.9 t
Louisiana average 32.3 t

Live comparison across Louisiana.

Historical Sufficiency Rating

PlainBridge-computed
85.3 / 100 - historical 80–100 band
Structural adequacy /55
51.9
Serviceability /30
29.2
Essentiality /15
12.3
Special reductions
−8.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
27.9 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1992
Material
Concrete
Number of Spans
3
Structure Length
17.4 m (57 ft)
Deck Width
12.2 m (40 ft)
Owner
County Highway Agency
Avg Daily Traffic
350 vehicles/day
Structure Number
611700000610083

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether E Grant St is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare E Grant St against other structures in East Baton Rouge and across Louisiana. Louisiana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for E Grant St?

E Grant St in East Baton Rouge, Louisiana has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is E Grant St inspected?

E Grant St's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 350 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. E Grant St is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for E Grant St?

E Grant St has an NBI inventory load rating of 27.9 metric tons.

Who is responsible for maintaining E Grant St?

E Grant St is owned and maintained by County Highway Agency.

How old is E Grant St and does age affect safety?

E Grant St was built in 1992, making it 34 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.