FHWA NBI 2024 Inspection record Public-domain dataset

LA0067

Carrying LA0067 over COMITE RIVER

1.8 Mi N of LA 412, East Feliciana, Louisiana

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
46 t Inventory load rating

Bridge Snapshot: LA0067

The LA0067 bridge in East Feliciana, Louisiana carries LA0067 over COMITE RIVER. It was built in 1965, making it 61 years old today. The structure is built primarily of prestressed concrete and spans 9 sections, stretching 165.2 meters (542 feet) end to end. Daily traffic averages 5,772 vehicles, placing it in the moderately-trafficked tier of Louisiana bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 8/9, substructure at 6/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 46.3 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How LA0067 compares

▲ 14.0
Load rating vs Louisiana average (32.3 t)
Top 9%
Higher load rating than 91% of Louisiana bridges
133
Bridges in East Feliciana · 34 in Poor condition
LA0067 46.3 t
Louisiana average 32.3 t

Live comparison across Louisiana.

Historical Sufficiency Rating

PlainBridge-computed
81.0 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
12.0
Essentiality /15
14.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
8/9
Good (7–9)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
46.3 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1965
Material
Prestressed Concrete
Number of Spans
9
Structure Length
165.2 m (542 ft)
Deck Width
10.2 m (33 ft)
Owner
State Highway Agency
Avg Daily Traffic
5,772 vehicles/day
Structure Number
611900600303721

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • At 8/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether LA0067 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare LA0067 against other structures in East Feliciana and across Louisiana. Louisiana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for LA0067?

LA0067 in East Feliciana, Louisiana has a deck rating of 6/9, superstructure rating of 8/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is LA0067 inspected?

LA0067's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 5,772 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. LA0067 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for LA0067?

LA0067 has an NBI inventory load rating of 46.3 metric tons.

Who is responsible for maintaining LA0067?

LA0067 is owned and maintained by State Highway Agency.

How old is LA0067 and does age affect safety?

LA0067 was built in 1965, making it 61 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.