FHWA NBI 2024 Inspection record Public-domain dataset

LA3066

Carrying LA3066 over CENTENNIAL CANAL

2.5 M SW of LA 1&LA 3066, Iberville, Louisiana

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
14 t Inventory load rating

Bridge Snapshot: LA3066

The LA3066 bridge in Iberville, Louisiana carries LA3066 over CENTENNIAL CANAL. It was built in 1968, making it 58 years old today. The structure is built primarily of concrete and spans 3 sections, stretching 17.7 meters (58 feet) end to end. Daily traffic averages 2,052 vehicles, placing it in the moderately-trafficked tier of Louisiana bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 4/9, substructure at 5/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 14.3 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How LA3066 compares

▼ 18.0
Load rating vs Louisiana average (32.3 t)
Bottom 6%
Lower load rating than 94% of Louisiana bridges
80
Bridges in Iberville · 12 in Poor condition
LA3066 14.3 t
Louisiana average 32.3 t

Live comparison across Louisiana.

Historical Sufficiency Rating

PlainBridge-computed
24.4 / 100 - historical 20–49.9 band
Structural adequacy /55
4.9
Serviceability /30
6.0
Essentiality /15
13.5
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
4/9
Poor (1–4)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
14.3 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1968
Material
Concrete
Number of Spans
3
Structure Length
17.7 m (58 ft)
Deck Width
8.7 m (29 ft)
Owner
State Highway Agency
Avg Daily Traffic
2,052 vehicles/day
Structure Number
612402300102701

Condition Analysis

  • The deck (driving surface) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • The substructure (piers and abutments) rates fair at 5/9, minor deterioration that routine maintenance should address.

How to read this record

LA3066 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare LA3066 against other structures in Iberville and across Louisiana. Louisiana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for LA3066?

LA3066 in Iberville, Louisiana has a deck rating of 4/9, superstructure rating of 4/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is LA3066 inspected?

LA3066's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 2,052 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. LA3066 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for LA3066?

LA3066 has an NBI inventory load rating of 14.3 metric tons.

Who is responsible for maintaining LA3066?

LA3066 is owned and maintained by State Highway Agency.

How old is LA3066 and does age affect safety?

LA3066 was built in 1968, making it 58 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.