FHWA NBI 2024 Inspection record Public-domain dataset

LA1026

Carrying LA1026 over CREEK

1.6 M SW OF LA 16, Livingston, Louisiana

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
11 t Inventory load rating

Bridge Snapshot: LA1026

The LA1026 bridge in Livingston, Louisiana carries LA1026 over CREEK. It was built in 1961, making it 65 years old today. The structure is built primarily of concrete and spans 2 sections, stretching 11.9 meters (39 feet) end to end. Daily traffic averages 8,669 vehicles, placing it in the moderately-trafficked tier of Louisiana bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 3/9, superstructure at 3/9, substructure at 4/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed. Its NBI inventory load rating is 11.0 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How LA1026 compares

▼ 21.3
Load rating vs Louisiana average (32.3 t)
Bottom 3%
Lower load rating than 97% of Louisiana bridges
253
Bridges in Livingston · 24 in Poor condition
LA1026 11.0 t
Louisiana average 32.3 t

Live comparison across Louisiana.

Historical Sufficiency Rating

PlainBridge-computed
17.0 / 100 - historical under-20 band
Structural adequacy /55
0.0
Serviceability /30
2.0
Essentiality /15
15.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
3/9
Poor (1–4)
Superstructure
3/9
Poor (1–4)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
11.0 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1961
Material
Concrete
Number of Spans
2
Structure Length
11.9 m (39 ft)
Deck Width
9.6 m (31 ft)
Owner
State Highway Agency
Avg Daily Traffic
8,669 vehicles/day
Structure Number
623202730302941

Condition Analysis

  • The deck (driving surface) is in poor condition (3/9), showing advanced deterioration that may require priority repair.
  • The superstructure (beams and supports above the deck) rates poor at 3/9, advanced deterioration that should be prioritized for repair.
  • At 4/9, the substructure (piers and abutments) is in poor shape, with advanced wear flagged for priority repair.

How to read this record

LA1026 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare LA1026 against other structures in Livingston and across Louisiana. Louisiana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for LA1026?

LA1026 in Livingston, Louisiana has a deck rating of 3/9, superstructure rating of 3/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is LA1026 inspected?

LA1026's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 8,669 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. LA1026 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for LA1026?

LA1026 has an NBI inventory load rating of 11.0 metric tons.

Who is responsible for maintaining LA1026?

LA1026 is owned and maintained by State Highway Agency.

How old is LA1026 and does age affect safety?

LA1026 was built in 1961, making it 65 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.