FHWA NBI 2024 Inspection record Public-domain dataset

LA0450

Carrying LA0450 over DRAIN

2.3 M N OF LA 10, Washington, Louisiana

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
10 t Inventory load rating

Bridge Snapshot: LA0450

The LA0450 bridge in Washington, Louisiana carries LA0450 over DRAIN. It was built in 1958, making it 68 years old today. The structure is built primarily of wood or timber and spans 3 sections, stretching 17.7 meters (58 feet) end to end. Daily traffic averages 1,162 vehicles, placing it in the moderately-trafficked tier of Louisiana bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 5/9, substructure at 3/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 10.2 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How LA0450 compares

▼ 22.1
Load rating vs Louisiana average (32.3 t)
Bottom 2%
Lower load rating than 98% of Louisiana bridges
285
Bridges in Washington · 33 in Poor condition
LA0450 10.2 t
Louisiana average 32.3 t

Live comparison across Louisiana.

Historical Sufficiency Rating

PlainBridge-computed
21.0 / 100 - historical 20–49.9 band
Structural adequacy /55
0.0
Serviceability /30
6.0
Essentiality /15
15.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
3/9
Poor (1–4)
Inventory Load Rating
10.2 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1958
Material
Wood or Timber
Number of Spans
3
Structure Length
17.7 m (58 ft)
Deck Width
8.0 m (26 ft)
Owner
State Highway Agency
Avg Daily Traffic
1,162 vehicles/day
Structure Number
625908590407161

Condition Analysis

  • At 5/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) is in poor condition (3/9), showing advanced deterioration that may require priority repair.

How to read this record

LA0450 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare LA0450 against other structures in Washington and across Louisiana. Louisiana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for LA0450?

LA0450 in Washington, Louisiana has a deck rating of 5/9, superstructure rating of 5/9, and substructure rating of 3/9 on the FHWA's 0–9 scale.

How often is LA0450 inspected?

LA0450's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,162 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. LA0450 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for LA0450?

LA0450 has an NBI inventory load rating of 10.2 metric tons.

Who is responsible for maintaining LA0450?

LA0450 is owned and maintained by State Highway Agency.

How old is LA0450 and does age affect safety?

LA0450 was built in 1958, making it 68 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.