FHWA NBI 2024 Inspection record Public-domain dataset

SR 91 TPK 258.2

Carrying SR 91 TPK 258.2 over SHINGLE CREEK

1.6 MILES S OF I-4, Orange, Florida

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
43 t Inventory load rating

Bridge Snapshot: SR 91 TPK 258.2

The SR 91 TPK 258.2 bridge in Orange, Florida carries SR 91 TPK 258.2 over SHINGLE CREEK. It was built in 2008, making it 18 years old today. The structure is built primarily of prestressed concrete and spans 3 sections, stretching 75.5 meters (248 feet) end to end. Daily traffic averages 121,200 vehicles, placing it in the heavily-trafficked tier of Florida bridges. It is owned and maintained by State Toll Authority.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 8/9, substructure at 7/9. The weakest component sits in good condition. All reported major components score above the Poor range. Its NBI inventory load rating is 42.5 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SR 91 TPK 258.2 compares

▲ 3.6
Load rating vs Florida average (38.9 t)
Top 30%
Higher load rating than 70% of Florida bridges
885
Bridges in Orange
SR 91 TPK 258.2 42.5 t
Florida average 38.9 t

Live comparison across Florida.

Historical Sufficiency Rating

PlainBridge-computed
80.9 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
25.0
Essentiality /15
0.9
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
8/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
42.5 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
2008
Material
Prestressed Concrete
Number of Spans
3
Structure Length
75.5 m (248 ft)
Deck Width
44.2 m (145 ft)
Owner
State Toll Authority
Avg Daily Traffic
121,200 vehicles/day
Structure Number
750625

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) is in good condition (8/9), showing no significant deterioration.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether SR 91 TPK 258.2 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SR 91 TPK 258.2 against other structures in Orange and across Florida. Florida bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR 91 TPK 258.2?

SR 91 TPK 258.2 in Orange, Florida has a deck rating of 7/9, superstructure rating of 8/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is SR 91 TPK 258.2 inspected?

SR 91 TPK 258.2's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 121,200 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR 91 TPK 258.2 is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR 91 TPK 258.2?

SR 91 TPK 258.2 has an NBI inventory load rating of 42.5 metric tons.

Who is responsible for maintaining SR 91 TPK 258.2?

SR 91 TPK 258.2 is owned and maintained by State Toll Authority.

How old is SR 91 TPK 258.2 and does age affect safety?

SR 91 TPK 258.2 was built in 2008, making it 18 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.