FHWA NBI 2024 Inspection record Public-domain dataset

WA3516 ANDERSON

Carrying WA3516 ANDERSON over HUGLE RUN

0.4 MI. N. OF CR112, Stark, Ohio

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
49 t Inventory load rating

Bridge Snapshot: WA3516 ANDERSON

The WA3516 ANDERSON bridge in Stark, Ohio carries WA3516 ANDERSON over HUGLE RUN. It was built in 1950, making it 76 years old today. It was last reconstructed in 1989, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 7.6 meters (25 feet) end to end. Daily traffic averages 168 vehicles, placing it in the lower-traffic tier of Ohio bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 5/9, substructure at 5/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 48.6 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How WA3516 ANDERSON compares

▲ 11.1
Load rating vs Ohio average (37.5 t)
Top 18%
Higher load rating than 82% of Ohio bridges
415
Bridges in Stark · 23 in Poor condition
WA3516 ANDERSON 48.6 t
Ohio average 37.5 t

Live comparison across Ohio.

Historical Sufficiency Rating

PlainBridge-computed
77.0 / 100 - historical 50–79.9 band
Structural adequacy /55
45.0
Serviceability /30
20.0
Essentiality /15
15.0
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
48.6 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1950
Last Reconstructed
1989
Material
Steel
Number of Spans
1
Structure Length
7.6 m (25 ft)
Deck Width
7.6 m (25 ft)
Owner
County Highway Agency
Avg Daily Traffic
168 vehicles/day
Structure Number
7634420

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) rates fair at 5/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether WA3516 ANDERSON is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare WA3516 ANDERSON against other structures in Stark and across Ohio. Ohio bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for WA3516 ANDERSON?

WA3516 ANDERSON in Stark, Ohio has a deck rating of 6/9, superstructure rating of 5/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is WA3516 ANDERSON inspected?

WA3516 ANDERSON's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 168 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. WA3516 ANDERSON is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for WA3516 ANDERSON?

WA3516 ANDERSON has an NBI inventory load rating of 48.6 metric tons.

Who is responsible for maintaining WA3516 ANDERSON?

WA3516 ANDERSON is owned and maintained by County Highway Agency.

How old is WA3516 ANDERSON and does age affect safety?

WA3516 ANDERSON was built in 1950, making it 76 years old and last reconstructed in 1989.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.