FHWA NBI 2024 Inspection record Public-domain dataset

PI2360 MAIN

Carrying PI2360 MAIN over NIMISHILLEN CREEK

0.1 MI. S. OF CR162, Stark, Ohio

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
42 t Inventory load rating

Bridge Snapshot: PI2360 MAIN

The PI2360 MAIN bridge in Stark, Ohio carries PI2360 MAIN over NIMISHILLEN CREEK. It was built in 2002, making it 24 years old today. The structure is built primarily of steel continuous and spans 3 sections, stretching 63.7 meters (209 feet) end to end. Daily traffic averages 1,761 vehicles, placing it in the moderately-trafficked tier of Ohio bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 8/9, substructure at 8/9. The weakest component sits in good condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 42.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How PI2360 MAIN compares

▲ 4.6
Load rating vs Ohio average (37.5 t)
Top 31%
Higher load rating than 69% of Ohio bridges
415
Bridges in Stark · 23 in Poor condition
PI2360 MAIN 42.1 t
Ohio average 37.5 t

Live comparison across Ohio.

Historical Sufficiency Rating

PlainBridge-computed
85.8 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
16.1
Essentiality /15
14.7
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
8/9
Good (7–9)
Substructure
8/9
Good (7–9)
Inventory Load Rating
42.1 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
2002
Material
Steel Continuous
Number of Spans
3
Structure Length
63.7 m (209 ft)
Deck Width
10.2 m (33 ft)
Owner
County Highway Agency
Avg Daily Traffic
1,761 vehicles/day
Structure Number
7635834

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • The superstructure (beams and supports above the deck) rates good at 8/9, with no significant deterioration on file.
  • The substructure (piers and abutments) rates good at 8/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether PI2360 MAIN is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare PI2360 MAIN against other structures in Stark and across Ohio. Ohio bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for PI2360 MAIN?

PI2360 MAIN in Stark, Ohio has a deck rating of 7/9, superstructure rating of 8/9, and substructure rating of 8/9 on the FHWA's 0–9 scale.

How often is PI2360 MAIN inspected?

PI2360 MAIN's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,761 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. PI2360 MAIN is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for PI2360 MAIN?

PI2360 MAIN has an NBI inventory load rating of 42.1 metric tons.

Who is responsible for maintaining PI2360 MAIN?

PI2360 MAIN is owned and maintained by County Highway Agency.

How old is PI2360 MAIN and does age affect safety?

PI2360 MAIN was built in 2002, making it 24 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.