FHWA NBI 2026 Inspection record Public-domain dataset

C340B CUNINGHM-ARB

Carrying C340B CUNINGHM-ARB over RUSH CREEK

.01MI E OF SHERTZER RD, Union, Ohio

FHWA NBI inspection record for this structure. Condition ratings, inventory load rating, span, deck width, and average daily traffic refresh annually with each NBI release.

Good
45 t Inventory load rating

Bridge Snapshot: C340B CUNINGHM-ARB

The C340B CUNINGHM-ARB bridge in Union, Ohio carries C340B CUNINGHM-ARB over RUSH CREEK. It was built in 2019, making it 7 years old today. The structure is built primarily of concrete continuous and spans 3 sections, stretching 37.2 meters (122 feet) end to end. Daily traffic averages 105 vehicles, placing it in the lower-traffic tier of Ohio bridges. It is owned and maintained by County Highway Agency, the entity responsible for routine inspections and any needed repairs.

The latest FHWA inspection records show a deck rating of 9/9, superstructure at 9/9, substructure at 9/9 on the 0–9 NBI scale, where 9 is excellent and 0 is failed. The weakest component sits in good condition, which drives the overall status of this bridge. No major component scores in the poor range, so the bridge is not classified as structurally deficient under federal criteria. Its NBI inventory load rating is 45.4 metric tons — the load level the structure is rated to carry at inventory (long-term) level.

In a county that maintains hundreds of NBI-tracked bridges, C340B CUNINGHM-ARB is one data point in a Ohio inventory that FHWA inspects on a two-year cycle (more often when ratings fall). Bridge age alone is not a reliable safety signal — a 7-era structure can outperform a newer one when maintenance is consistent, materials are sound, and traffic loads stay within design limits. Use the condition ratings above, the sufficiency score, and the structurally-deficient flag together to read the bridge's real status, and check the linked county and state pages to see how this bridge ranks against its peers.

Every figure on this page comes directly from the Federal Highway Administration National Bridge Inventory (NBI), the public dataset that catalogs more than 617,000 highway bridges across the United States and is updated annually from the records that each state Department of Transportation submits to the FHWA. The condition codes use the standardized FHWA Recording and Coding Guide, the same scale that determines federal eligibility for the Highway Bridge Program and the Surface Transportation Block Grant set-aside for off-system bridges. A "structurally deficient" classification under those federal criteria is a maintenance and funding flag, never a closure order; states keep deficient bridges open with load posting, weight limits, or accelerated inspection cycles until rehabilitation or replacement is funded. See our methodology for refresh cadence and the exact NBI release vintage powering each record.

How C340B CUNINGHM-ARB compares

▲ 7.9
Load rating vs Ohio average (37.5 t)
Top 24%
Higher load rating than 76% of Ohio bridges
221
Bridges in Union · 2 structurally deficient
C340B CUNINGHM-ARB 45.4 t
Ohio average 37.5 t

NBI inventory load rating (metric tons) and structural-deficiency status compared across Ohio, computed live from the FHWA NBI.

Condition Ratings

Deck
9/9
Good (7–9)
Superstructure
9/9
Good (7–9)
Substructure
9/9
Good (7–9)
Inventory Load Rating
45.4 t
NBI inventory level (metric tons)
SD Status
Not SD

Ratings are on a 0–9 scale: 9 = Excellent, 7–8 = Good, 5–6 = Fair, 3–4 = Poor, 0–2 = Critical/Failed. Sufficiency rating (0–100) combines structural adequacy, functional obsolescence, and essentiality.

Structural Details

Year Built
2019
Material
Concrete Continuous
Number of Spans
3
Structure Length
37.2 m (122 ft)
Deck Width
9.1 m (30 ft)
Owner
County Highway Agency
Avg Daily Traffic
105 vehicles/day
Structure Number
8037788

Location

.01MI E OF SHERTZER RD, Union, Ohio
40.481761, -83.433681
View on Google Maps ↗

Data Source

Data from the FHWA National Bridge Inventory (NBI). Bridge inspections are required every two years by federal law. Conditions reflect the most recent inspection.

FHWA NBI Program ↗

Condition Analysis

Built in 2019, this bridge is 7 years old. It carries approximately 105 vehicles per day. Based on the most recent FHWA inspection:

  • The deck (driving surface) is in good condition (9/9), showing no significant deterioration.
  • The superstructure (beams and supports above the deck) is in good condition (9/9), showing no significant deterioration.
  • The substructure (piers and abutments) is in good condition (9/9), showing no significant deterioration.

Its NBI inventory load rating reflects the load level it is rated to carry.

Frequently Asked Questions

What do the condition ratings mean for C340B CUNINGHM-ARB?

Bridge condition ratings use a 0–9 scale set by the Federal Highway Administration (FHWA). Ratings 7–9 indicate good condition with no significant problems. Ratings 5–6 mean fair condition with minor issues. Ratings 3–4 indicate poor condition requiring repair. Ratings 0–2 are critical, meaning the bridge has serious structural problems. C340B CUNINGHM-ARB in Union, Ohio has a deck rating of 9/9, superstructure rating of 9/9, and substructure rating of 9/9.

How often is C340B CUNINGHM-ARB inspected?

Federal law requires most highway bridges to be inspected at least every 24 months. Bridges in poor condition or with known issues may be inspected more frequently (every 12 months or less). C340B CUNINGHM-ARB is part of the National Bridge Inventory maintained by the FHWA. With 105 vehicles crossing daily, regular inspection is essential.

What does "structurally deficient" mean for a bridge?

A structurally deficient bridge has at least one major component (deck, superstructure, or substructure) rated 4 or below on the FHWA 0–9 scale. This classification does NOT mean the bridge is unsafe for travel — it means the bridge needs repair, rehabilitation, or eventual replacement. Structurally deficient bridges remain open and are monitored. C340B CUNINGHM-ARB is not classified as structurally deficient.

What is the inventory load rating for C340B CUNINGHM-ARB?

The NBI inventory rating is the load level a bridge is rated to carry for an indefinite period, recorded in metric tons. A lower number means the structure is more load-restricted. C340B CUNINGHM-ARB has an inventory load rating of 45.4 metric tons. It is distinct from the FHWA sufficiency rating, a separate 0–100 funding-eligibility score that this dataset does not include.

Who is responsible for maintaining C340B CUNINGHM-ARB?

Bridge ownership and maintenance responsibility varies — bridges may be owned by state DOTs, counties, cities, railroads, or federal agencies. C340B CUNINGHM-ARB is maintained by County Highway Agency. The FHWA oversees the National Bridge Inventory program and sets inspection standards, but day-to-day maintenance falls to the owning agency. If you notice damage or safety concerns, contact your state DOT or call 911 for emergencies.

How old is C340B CUNINGHM-ARB and does age affect safety?

C340B CUNINGHM-ARB was built in 2019, making it 7 years old. Bridge age alone does not determine safety — condition depends on materials, design, traffic load, maintenance history, and environmental exposure. Many older bridges remain in good condition due to regular maintenance and reconstruction.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A structurally deficient rating does not mean a bridge is closed or unsafe for travel — it indicates the bridge requires repair or replacement. For current closure or safety information, contact your state DOT.

Related

Data sourced from official U.S. government datasets. See our methodology for details. Retrieved and formatted by PlainBridges Editorial