FHWA NBI 2024 Inspection record Public-domain dataset

19TH ST. BESSEMER

Carrying 19TH ST. BESSEMER over VALLEY CREEK

19TH ST. * VALLEY CREEK, Jefferson, Alabama

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
20 t Inventory load rating Lower than 90% of rated Alabama bridges

19TH ST. BESSEMER in Jefferson, Alabama sits above 10% of rated Alabama bridges on inventory load rating (20 t), while its 1955 build year is earlier than 80% of Jefferson's recorded-year cohort (1,068 bridges).

19TH ST. BESSEMER in Jefferson, Alabama is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1955, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure AL:005321

INTERSTATE-ERA · CONCRETE · MULTI-SPAN · SUB-LED · ARTERIAL-ADT · STANDARD-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • CONCRETE Concrete
  • MULTI-SPAN 3 spans
  • SUB-LED Substructure-led
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: 19TH ST. BESSEMER

The 19TH ST. BESSEMER bridge in Jefferson, Alabama carries 19TH ST. BESSEMER over VALLEY CREEK. It was built in 1955, making it 71 years old today. The structure is built primarily of concrete and spans 3 sections, stretching 31.4 meters (103 feet) end to end. Daily traffic averages 5,000 vehicles, placing it in the moderately-trafficked tier of Alabama bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 5/9. The weakest component sits in fair condition. All reported major components score above the Poor range.

How 19TH ST. BESSEMER compares

▼ 17.6
Load rating vs Alabama average (37.6 t; 16,191 of 16,205 rated)
1,068
Bridges in Jefferson · 24 in Poor condition

Age against the county: built in 1955, earlier than 855 of Jefferson's 1,068 bridges with a recorded construction year (80%), against a county median build year of 1974. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

19TH ST. BESSEMER 20.0 t
Alabama average (16,191 of 16,205 rated) 37.6 t

Live comparison across Alabama bridges with a recorded inventory load rating (16,191 of 16,205 rated).

19TH ST. BESSEMER vs every rated Alabama bridge

Inventory load rating (metric tons), FHWA NBI, this state

20 Top 90% higher than 10% of 16,191 bridges

rated Alabama bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
20.0 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Jefferson inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 1,068 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1955
Material
Concrete
Number of Spans
3
Structure Length
31.4 m (103 ft)
Deck Width
15.0 m (49 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
5,000 vehicles/day
Structure Number
005321

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether 19TH ST. BESSEMER is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare 19TH ST. BESSEMER against other structures in Jefferson and across Alabama. Alabama bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for 19TH ST. BESSEMER?

19TH ST. BESSEMER in Jefferson, Alabama has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is 19TH ST. BESSEMER inspected?

19TH ST. BESSEMER's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 5,000 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. 19TH ST. BESSEMER is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for 19TH ST. BESSEMER?

19TH ST. BESSEMER has an NBI inventory load rating of 20.0 metric tons.

Who is responsible for maintaining 19TH ST. BESSEMER?

19TH ST. BESSEMER is owned and maintained by City/Municipal Highway Agency.

How old is 19TH ST. BESSEMER and does age affect safety?

19TH ST. BESSEMER was built in 1955, making it 71 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.