FHWA NBI 2024 Inspection record Public-domain dataset

I 80W

Carrying I 80W over HUMBOLDT RVR

WEST OF ELKO, Elko, Nevada

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
39 t Inventory load rating

Bridge Snapshot: I 80W

The I 80W bridge in Elko, Nevada carries I 80W over HUMBOLDT RVR. It was built in 1971, making it 55 years old today. It was last reconstructed in 1980, extending its service life. The structure is built primarily of steel continuous and spans 3 sections, stretching 112.8 meters (370 feet) end to end. Daily traffic averages 5,650 vehicles, placing it in the moderately-trafficked tier of Nevada bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 39.2 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How I 80W compares

▼ 7.4
Load rating vs Nevada average (46.6 t)
Bottom 47%
Lower load rating than 53% of Nevada bridges
224
Bridges in Elko · 6 in Poor condition
I 80W 39.2 t
Nevada average 46.6 t

Live comparison across Nevada.

Historical Sufficiency Rating

PlainBridge-computed
80.7 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
13.0
Essentiality /15
12.7
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
39.2 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1971
Last Reconstructed
1980
Material
Steel Continuous
Number of Spans
3
Structure Length
112.8 m (370 ft)
Deck Width
11.2 m (37 ft)
Owner
State Highway Agency
Avg Daily Traffic
5,650 vehicles/day
Structure Number
B1111W

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) rates good at 7/9, with no significant deterioration on file.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether I 80W is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare I 80W against other structures in Elko and across Nevada. Nevada bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for I 80W?

I 80W in Elko, Nevada has a deck rating of 6/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is I 80W inspected?

I 80W's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 5,650 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. I 80W is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for I 80W?

I 80W has an NBI inventory load rating of 39.2 metric tons.

Who is responsible for maintaining I 80W?

I 80W is owned and maintained by State Highway Agency.

How old is I 80W and does age affect safety?

I 80W was built in 1971, making it 55 years old and last reconstructed in 1980.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.