FHWA NBI 2024 Inspection record Public-domain dataset

STH 165 WB

Carrying STH 165 WB over SOO LINE RR

0.2M W JCT CTH H, Kenosha, Wisconsin

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
36 t Inventory load rating

Bridge Snapshot: STH 165 WB

The STH 165 WB bridge in Kenosha, Wisconsin carries STH 165 WB over SOO LINE RR. It was built in 1989, making it 37 years old today. The structure is built primarily of prestressed concrete continuous and spans 3 sections, stretching 49.9 meters (164 feet) end to end. Daily traffic averages 6,800 vehicles, placing it in the moderately-trafficked tier of Wisconsin bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 35.6 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How STH 165 WB compares

▲ 2.3
Load rating vs Wisconsin average (33.3 t)
Top 45%
Higher load rating than 55% of Wisconsin bridges
121
Bridges in Kenosha · 4 in Poor condition
STH 165 WB 35.6 t
Wisconsin average 33.3 t

Live comparison across Wisconsin.

Historical Sufficiency Rating

PlainBridge-computed
96.7 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
30.0
Essentiality /15
14.7
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
35.6 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1989
Material
Prestressed Concrete Continuous
Number of Spans
3
Structure Length
49.9 m (164 ft)
Deck Width
12.2 m (40 ft)
Owner
State Highway Agency
Avg Daily Traffic
6,800 vehicles/day
Structure Number
B30006700000000

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) rates good at 7/9, with no significant deterioration on file.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether STH 165 WB is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare STH 165 WB against other structures in Kenosha and across Wisconsin. Wisconsin bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for STH 165 WB?

STH 165 WB in Kenosha, Wisconsin has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is STH 165 WB inspected?

STH 165 WB's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 6,800 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. STH 165 WB is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for STH 165 WB?

STH 165 WB has an NBI inventory load rating of 35.6 metric tons.

Who is responsible for maintaining STH 165 WB?

STH 165 WB is owned and maintained by State Highway Agency.

How old is STH 165 WB and does age affect safety?

STH 165 WB was built in 1989, making it 37 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.