FHWA NBI 2024 Inspection record Public-domain dataset

US 85 ML SBND

Carrying US 85 ML SBND over SOUTH PLATTE RIVER

S. EDGE OF EVANS, Weld, Colorado

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
30 t Inventory load rating

Bridge Snapshot: US 85 ML SBND

The US 85 ML SBND bridge in Weld, Colorado carries US 85 ML SBND over SOUTH PLATTE RIVER. It was built in 1955, making it 71 years old today. The structure is built primarily of concrete and spans 19 sections, stretching 290.2 meters (952 feet) end to end. Daily traffic averages 12,500 vehicles, placing it in the heavily-trafficked tier of Colorado bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 5/9, substructure at 4/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 29.5 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How US 85 ML SBND compares

▼ 7.6
Load rating vs Colorado average (37.1 t)
Bottom 32%
Lower load rating than 68% of Colorado bridges
614
Bridges in Weld · 25 in Poor condition
US 85 ML SBND 29.5 t
Colorado average 37.1 t

Live comparison across Colorado.

Historical Sufficiency Rating

PlainBridge-computed
53.1 / 100 - historical 50–79.9 band
Structural adequacy /55
28.4
Serviceability /30
11.0
Essentiality /15
13.7
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
29.5 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1955
Material
Concrete
Number of Spans
19
Structure Length
290.2 m (952 ft)
Deck Width
10.7 m (35 ft)
Owner
State Highway Agency
Avg Daily Traffic
12,500 vehicles/day
Structure Number
C-18-AG

Condition Analysis

  • The deck (driving surface) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) rates poor at 4/9, advanced deterioration that should be prioritized for repair.

How to read this record

US 85 ML SBND is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare US 85 ML SBND against other structures in Weld and across Colorado. Colorado bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for US 85 ML SBND?

US 85 ML SBND in Weld, Colorado has a deck rating of 6/9, superstructure rating of 5/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is US 85 ML SBND inspected?

US 85 ML SBND's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 12,500 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. US 85 ML SBND is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for US 85 ML SBND?

US 85 ML SBND has an NBI inventory load rating of 29.5 metric tons.

Who is responsible for maintaining US 85 ML SBND?

US 85 ML SBND is owned and maintained by State Highway Agency.

How old is US 85 ML SBND and does age affect safety?

US 85 ML SBND was built in 1955, making it 71 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.