FHWA NBI 2024 Inspection record Public-domain dataset

FAS 2765

Carrying FAS 2765 over SCHOOL CREEK

JCT US6/81 1.1N 11W, Fillmore, Nebraska

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
25 t Inventory load rating

Bridge Snapshot: FAS 2765

The FAS 2765 bridge in Fillmore, Nebraska carries FAS 2765 over SCHOOL CREEK. It was built in 1982, making it 44 years old today. The structure is built primarily of steel and spans 1 section, stretching 19.2 meters (63 feet) end to end. Daily traffic averages 120 vehicles, placing it in the lower-traffic tier of Nebraska bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 8/9, superstructure at 8/9, substructure at 8/9. The weakest component sits in good condition. All reported major components score above the Poor range. Its NBI inventory load rating is 25.0 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How FAS 2765 compares

▼ 2.7
Load rating vs Nebraska average (27.7 t)
Bottom 47%
Lower load rating than 53% of Nebraska bridges
218
Bridges in Fillmore · 19 in Poor condition
FAS 2765 25.0 t
Nebraska average 27.7 t

Live comparison across Nebraska.

Historical Sufficiency Rating

PlainBridge-computed
93.3 / 100 - historical 80–100 band
Structural adequacy /55
48.4
Serviceability /30
30.0
Essentiality /15
14.8
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
8/9
Good (7–9)
Superstructure
8/9
Good (7–9)
Substructure
8/9
Good (7–9)
Inventory Load Rating
25.0 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1982
Material
Steel
Number of Spans
1
Structure Length
19.2 m (63 ft)
Deck Width
9.4 m (31 ft)
Owner
County Highway Agency
Avg Daily Traffic
120 vehicles/day
Structure Number
C003000315

Condition Analysis

  • The deck (driving surface) rates good at 8/9, with no significant deterioration on file.
  • At 8/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • At 8/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether FAS 2765 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare FAS 2765 against other structures in Fillmore and across Nebraska. Nebraska bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for FAS 2765?

FAS 2765 in Fillmore, Nebraska has a deck rating of 8/9, superstructure rating of 8/9, and substructure rating of 8/9 on the FHWA's 0–9 scale.

How often is FAS 2765 inspected?

FAS 2765's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 120 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. FAS 2765 is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for FAS 2765?

FAS 2765 has an NBI inventory load rating of 25.0 metric tons.

Who is responsible for maintaining FAS 2765?

FAS 2765 is owned and maintained by County Highway Agency.

How old is FAS 2765 and does age affect safety?

FAS 2765 was built in 1982, making it 44 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.