FHWA NBI 2024 Inspection record Public-domain dataset

PIONEERS BLVD

Carrying PIONEERS BLVD over STEVENS CREEK (Q 72)

2S 1E OF WALTON, Lancaster, Nebraska

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
27 t Inventory load rating

Bridge Snapshot: PIONEERS BLVD

The PIONEERS BLVD bridge in Lancaster, Nebraska carries PIONEERS BLVD over STEVENS CREEK (Q 72). It was built in 1971, making it 55 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 13.4 meters (44 feet) end to end. Daily traffic averages 152 vehicles, placing it in the lower-traffic tier of Nebraska bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. All reported major components score above the Poor range. Its NBI inventory load rating is 27.0 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How PIONEERS BLVD compares

▼ 0.7
Load rating vs Nebraska average (27.7 t)
Top 49%
Higher load rating than 51% of Nebraska bridges
684
Bridges in Lancaster · 27 in Poor condition
PIONEERS BLVD 27.0 t
Nebraska average 27.7 t

Live comparison across Nebraska.

Historical Sufficiency Rating

PlainBridge-computed
91.7 / 100 - historical 80–100 band
Structural adequacy /55
50.9
Serviceability /30
29.0
Essentiality /15
14.8
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
27.0 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1971
Material
Prestressed Concrete
Number of Spans
1
Structure Length
13.4 m (44 ft)
Deck Width
9.1 m (30 ft)
Owner
County Highway Agency
Avg Daily Traffic
152 vehicles/day
Structure Number
C005524025

Condition Analysis

  • The deck (driving surface) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) rates fair at 6/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether PIONEERS BLVD is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare PIONEERS BLVD against other structures in Lancaster and across Nebraska. Nebraska bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for PIONEERS BLVD?

PIONEERS BLVD in Lancaster, Nebraska has a deck rating of 5/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is PIONEERS BLVD inspected?

PIONEERS BLVD's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 152 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. PIONEERS BLVD is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for PIONEERS BLVD?

PIONEERS BLVD has an NBI inventory load rating of 27.0 metric tons.

Who is responsible for maintaining PIONEERS BLVD?

PIONEERS BLVD is owned and maintained by County Highway Agency.

How old is PIONEERS BLVD and does age affect safety?

PIONEERS BLVD was built in 1971, making it 55 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.