FHWA NBI 2024 Inspection record Public-domain dataset

240TH ST/COLL 7927

Carrying 240TH ST/COLL 7927 over STREAM

2W 1N GRETNA, Sarpy, Nebraska

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
22 t Inventory load rating

Bridge Snapshot: 240TH ST/COLL 7927

The 240TH ST/COLL 7927 bridge in Sarpy, Nebraska carries 240TH ST/COLL 7927 over STREAM. It was built in 1970, making it 56 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 7.3 meters (24 feet) end to end. Daily traffic averages 100 vehicles, placing it in the lower-traffic tier of Nebraska bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 22.0 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How 240TH ST/COLL 7927 compares

▼ 5.7
Load rating vs Nebraska average (27.7 t)
Bottom 22%
Lower load rating than 78% of Nebraska bridges
197
Bridges in Sarpy · 17 in Poor condition
240TH ST/COLL 7927 22.0 t
Nebraska average 27.7 t

Live comparison across Nebraska.

Historical Sufficiency Rating

PlainBridge-computed
79.2 / 100 - historical 50–79.9 band
Structural adequacy /55
44.1
Serviceability /30
29.0
Essentiality /15
14.1
Special reductions
−8.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
22.0 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1970
Material
Prestressed Concrete
Number of Spans
1
Structure Length
7.3 m (24 ft)
Deck Width
9.2 m (30 ft)
Owner
County Highway Agency
Avg Daily Traffic
100 vehicles/day
Structure Number
C007700510

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether 240TH ST/COLL 7927 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare 240TH ST/COLL 7927 against other structures in Sarpy and across Nebraska. Nebraska bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for 240TH ST/COLL 7927?

240TH ST/COLL 7927 in Sarpy, Nebraska has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is 240TH ST/COLL 7927 inspected?

240TH ST/COLL 7927's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 100 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. 240TH ST/COLL 7927 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for 240TH ST/COLL 7927?

240TH ST/COLL 7927 has an NBI inventory load rating of 22.0 metric tons.

Who is responsible for maintaining 240TH ST/COLL 7927?

240TH ST/COLL 7927 is owned and maintained by County Highway Agency.

How old is 240TH ST/COLL 7927 and does age affect safety?

240TH ST/COLL 7927 was built in 1970, making it 56 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.