FHWA NBI 2024 Inspection record Public-domain dataset

SR 175 WB

Carrying SR 175 WB over HILLSIDE

01-MEN-175-8.50, Mendocino, California

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Good
36 t Inventory load rating Higher than 79% of rated California bridges

SR 175 WB in Mendocino, California sits above 79% of rated California bridges on inventory load rating (36 t), while its 1986 build year is earlier than 23% of Mendocino's recorded-year cohort (357 bridges).

SR 175 WB in Mendocino, California is rated Good in the FHWA's 2024 National Bridge Inventory. Built in 1986, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 7. The lowest applicable rating sets the federal condition category, so this Good result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure CA:10 0275

LATE-CENTURY · CONCRETE · LONG-SPAN-RUN · TIED-CTRL · ARTERIAL-ADT · STANDARD-LOAD · CAT-GOOD

  • LATE-CENTURY 1980–1999
  • CONCRETE Concrete
  • LONG-SPAN-RUN 11 spans
  • TIED-CTRL Tied control
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-GOOD Good

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: SR 175 WB

The SR 175 WB bridge in Mendocino, California carries SR 175 WB over HILLSIDE. It was built in 1986, making it 40 years old today. The structure is built primarily of concrete continuous and spans 11 sections, stretching 57.6 meters (189 feet) end to end. Daily traffic averages 4,800 vehicles, placing it in the moderately-trafficked tier of California bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. None of this bridge's reported major components fall into the Poor condition range.

How SR 175 WB compares

▲ 3.5
Load rating vs California average (32.1 t; 25,538 of 25,848 rated)
357
Bridges in Mendocino · 27 in Poor condition

Age against the county: built in 1986, earlier than 82 of Mendocino's 357 bridges with a recorded construction year (23%), against a county median build year of 1964. This is one of the newer structures in its county.

SR 175 WB 35.6 t
California average (25,538 of 25,848 rated) 32.1 t

Live comparison across California bridges with a recorded inventory load rating (25,538 of 25,848 rated).

SR 175 WB vs every rated California bridge

Inventory load rating (metric tons), FHWA NBI, this state

36 Top 21% higher than 79% of 25,538 bridges

rated California bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
35.6 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Mendocino inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 357 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1986
Material
Concrete Continuous
Number of Spans
11
Structure Length
57.6 m (189 ft)
Deck Width
2.4 m (8 ft)
Owner
State Highway Agency
Avg Daily Traffic
4,800 vehicles/day
Structure Number
10 0275

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) rates good at 7/9, with no significant deterioration on file.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether SR 175 WB is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SR 175 WB against other structures in Mendocino and across California. California bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR 175 WB?

SR 175 WB in Mendocino, California has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is SR 175 WB inspected?

SR 175 WB's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 4,800 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR 175 WB is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR 175 WB?

SR 175 WB has an NBI inventory load rating of 35.6 metric tons.

Who is responsible for maintaining SR 175 WB?

SR 175 WB is owned and maintained by State Highway Agency.

How old is SR 175 WB and does age affect safety?

SR 175 WB was built in 1986, making it 40 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.