FHWA NBI 2024 Inspection record Public-domain dataset

INTERSTATE 80 EB

Carrying INTERSTATE 80 EB over HAMPSHIRE ROCKS S YUBA R

03-PLA-080-R64.54R, Placer, California

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
29 t Inventory load rating Lower than 70% of rated California bridges

INTERSTATE 80 EB in Placer, California sits above 30% of rated California bridges on inventory load rating (29 t), while its 1963 build year is earlier than 65% of Placer's recorded-year cohort (337 bridges).

INTERSTATE 80 EB in Placer, California is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1963, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure CA:19 0121R

INTERSTATE-ERA · STEEL · LONG-SPAN-RUN · SUB-LED · HEAVY-ADT · STANDARD-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • LONG-SPAN-RUN 4 spans
  • SUB-LED Substructure-led
  • HEAVY-ADT Heavy ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: INTERSTATE 80 EB

The INTERSTATE 80 EB bridge in Placer, California carries INTERSTATE 80 EB over HAMPSHIRE ROCKS S YUBA R. It was built in 1963, making it 63 years old today. The structure is built primarily of steel and spans 4 sections, stretching 125.9 meters (413 feet) end to end. Daily traffic averages 27,000 vehicles, placing it in the heavily-trafficked tier of California bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 5/9, substructure at 4/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules.

How INTERSTATE 80 EB compares

▼ 2.9
Load rating vs California average (32.1 t; 25,538 of 25,848 rated)
337
Bridges in Placer · 14 in Poor condition

Age against the county: built in 1963, earlier than 218 of Placer's 337 bridges with a recorded construction year (65%), against a county median build year of 1973. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

INTERSTATE 80 EB 29.2 t
California average (25,538 of 25,848 rated) 32.1 t

Live comparison across California bridges with a recorded inventory load rating (25,538 of 25,848 rated).

INTERSTATE 80 EB vs every rated California bridge

Inventory load rating (metric tons), FHWA NBI, this state

29 Top 70% higher than 30% of 25,538 bridges

rated California bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
29.2 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Placer inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 337 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1963
Material
Steel
Number of Spans
4
Structure Length
125.9 m (413 ft)
Deck Width
14.4 m (47 ft)
Owner
State Highway Agency
Avg Daily Traffic
27,000 vehicles/day
Structure Number
19 0121R

Condition Analysis

  • At 5/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) rates poor at 4/9, with advanced deterioration recorded on the latest inspection.

How to read this record

INTERSTATE 80 EB is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare INTERSTATE 80 EB against other structures in Placer and across California. California bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for INTERSTATE 80 EB?

INTERSTATE 80 EB in Placer, California has a deck rating of 5/9, superstructure rating of 5/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is INTERSTATE 80 EB inspected?

INTERSTATE 80 EB's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 27,000 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. INTERSTATE 80 EB is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for INTERSTATE 80 EB?

INTERSTATE 80 EB has an NBI inventory load rating of 29.2 metric tons.

Who is responsible for maintaining INTERSTATE 80 EB?

INTERSTATE 80 EB is owned and maintained by State Highway Agency.

How old is INTERSTATE 80 EB and does age affect safety?

INTERSTATE 80 EB was built in 1963, making it 63 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.