FHWA NBI 2024 Inspection record Public-domain dataset

FOSTORIA PARKWAY

Carrying FOSTORIA PARKWAY over INTERSTATE 680

04-CC-680-R4.38-SRMN, Contra Costa, California

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
32 t Inventory load rating Lower than 63% of rated California bridges

FOSTORIA PARKWAY in Contra Costa, California sits above 37% of rated California bridges on inventory load rating (32 t), while its 1992 build year is earlier than 28% of Contra Costa's recorded-year cohort (618 bridges).

FOSTORIA PARKWAY in Contra Costa, California is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1992, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure CA:28 0316

LATE-CENTURY · PRESTRESS · MULTI-SPAN · SUPER-LED · ARTERIAL-ADT · STANDARD-LOAD · CAT-FAIR

  • LATE-CENTURY 1980–1999
  • PRESTRESS Prestressed concrete
  • MULTI-SPAN 2 spans
  • SUPER-LED Superstructure-led
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: FOSTORIA PARKWAY

The FOSTORIA PARKWAY bridge in Contra Costa, California carries FOSTORIA PARKWAY over INTERSTATE 680. It was built in 1992, making it 34 years old today. The structure is built primarily of prestressed concrete continuous and spans 2 sections, stretching 100.9 meters (331 feet) end to end. Daily traffic averages 8,400 vehicles, placing it in the moderately-trafficked tier of California bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 5/9, substructure at 7/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range.

How FOSTORIA PARKWAY compares

▲ 0.3
Load rating vs California average (32.1 t; 25,538 of 25,848 rated)
618
Bridges in Contra Costa · 65 in Poor condition

Age against the county: built in 1992, earlier than 170 of Contra Costa's 618 bridges with a recorded construction year (28%), against a county median build year of 1971. This is one of the newer structures in its county.

FOSTORIA PARKWAY 32.4 t
California average (25,538 of 25,848 rated) 32.1 t

Live comparison across California bridges with a recorded inventory load rating (25,538 of 25,848 rated).

FOSTORIA PARKWAY vs every rated California bridge

Inventory load rating (metric tons), FHWA NBI, this state

32 Top 63% higher than 37% of 25,538 bridges

rated California bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
5/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
32.4 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Contra Costa inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 618 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1992
Material
Prestressed Concrete Continuous
Number of Spans
2
Structure Length
100.9 m (331 ft)
Deck Width
30.5 m (100 ft)
Owner
State Highway Agency
Avg Daily Traffic
8,400 vehicles/day
Structure Number
28 0316

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether FOSTORIA PARKWAY is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare FOSTORIA PARKWAY against other structures in Contra Costa and across California. California bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for FOSTORIA PARKWAY?

FOSTORIA PARKWAY in Contra Costa, California has a deck rating of 7/9, superstructure rating of 5/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is FOSTORIA PARKWAY inspected?

FOSTORIA PARKWAY's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 8,400 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. FOSTORIA PARKWAY is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for FOSTORIA PARKWAY?

FOSTORIA PARKWAY has an NBI inventory load rating of 32.4 metric tons.

Who is responsible for maintaining FOSTORIA PARKWAY?

FOSTORIA PARKWAY is owned and maintained by State Highway Agency.

How old is FOSTORIA PARKWAY and does age affect safety?

FOSTORIA PARKWAY was built in 1992, making it 34 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.