FHWA NBI 2024 Inspection record Public-domain dataset

ALMADEN EXPWAY

Carrying ALMADEN EXPWAY over CALTRAIN UP RR AMTRAK

AT UP RR, Santa Clara, California

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Good
32 t Inventory load rating Lower than 63% of rated California bridges

ALMADEN EXPWAY in Santa Clara, California sits above 37% of rated California bridges on inventory load rating (32 t), while its 1990 build year is earlier than 26% of Santa Clara's recorded-year cohort (964 bridges).

ALMADEN EXPWAY in Santa Clara, California is rated Good in the FHWA's 2024 National Bridge Inventory. Built in 1990, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 7. The lowest applicable rating sets the federal condition category, so this Good result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure CA:37C0026

LATE-CENTURY · PRESTRESS · MULTI-SPAN · TIED-CTRL · HEAVY-ADT · STANDARD-LOAD · CAT-GOOD

  • LATE-CENTURY 1980–1999
  • PRESTRESS Prestressed concrete
  • MULTI-SPAN 2 spans
  • TIED-CTRL Tied control
  • HEAVY-ADT Heavy ADT
  • STANDARD-LOAD Standard load
  • CAT-GOOD Good

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: ALMADEN EXPWAY

The ALMADEN EXPWAY bridge in Santa Clara, California carries ALMADEN EXPWAY over CALTRAIN UP RR AMTRAK. It was built in 1990, making it 36 years old today. The structure is built primarily of prestressed concrete continuous and spans 2 sections, stretching 37.2 meters (122 feet) end to end. Daily traffic averages 39,804 vehicles, placing it in the heavily-trafficked tier of California bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. All reported major components score above the Poor range.

How ALMADEN EXPWAY compares

▲ 0.3
Load rating vs California average (32.1 t; 25,538 of 25,848 rated)
964
Bridges in Santa Clara · 54 in Poor condition

Age against the county: built in 1990, earlier than 248 of Santa Clara's 964 bridges with a recorded construction year (26%), against a county median build year of 1972. This is one of the newer structures in its county.

ALMADEN EXPWAY 32.4 t
California average (25,538 of 25,848 rated) 32.1 t

Live comparison across California bridges with a recorded inventory load rating (25,538 of 25,848 rated).

ALMADEN EXPWAY vs every rated California bridge

Inventory load rating (metric tons), FHWA NBI, this state

32 Top 63% higher than 37% of 25,538 bridges

rated California bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
32.4 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Santa Clara inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 964 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1990
Material
Prestressed Concrete Continuous
Number of Spans
2
Structure Length
37.2 m (122 ft)
Deck Width
26.7 m (88 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
39,804 vehicles/day
Structure Number
37C0026

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether ALMADEN EXPWAY is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare ALMADEN EXPWAY against other structures in Santa Clara and across California. California bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for ALMADEN EXPWAY?

ALMADEN EXPWAY in Santa Clara, California has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is ALMADEN EXPWAY inspected?

ALMADEN EXPWAY's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 39,804 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. ALMADEN EXPWAY is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for ALMADEN EXPWAY?

ALMADEN EXPWAY has an NBI inventory load rating of 32.4 metric tons.

Who is responsible for maintaining ALMADEN EXPWAY?

ALMADEN EXPWAY is owned and maintained by City/Municipal Highway Agency.

How old is ALMADEN EXPWAY and does age affect safety?

ALMADEN EXPWAY was built in 1990, making it 36 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.