FHWA NBI 2024 Inspection record Public-domain dataset

ROSECRANS AVE W

Carrying ROSECRANS AVE W over LOS ANGELES RIV

0.1MI E/O I-710 FWY, Los Angeles, California

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
27 t Inventory load rating Lower than 74% of rated California bridges

ROSECRANS AVE W in Los Angeles, California sits above 26% of rated California bridges on inventory load rating (27 t), while its 1951 build year is earlier than 86% of Los Angeles's recorded-year cohort (3,547 bridges).

ROSECRANS AVE W in Los Angeles, California is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1951, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure CA:53C0190L

INTERSTATE-ERA · CONCRETE · LONG-SPAN-RUN · DECK-LED · HEAVY-ADT · STANDARD-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • CONCRETE Concrete
  • LONG-SPAN-RUN 8 spans
  • DECK-LED Deck-led
  • HEAVY-ADT Heavy ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: ROSECRANS AVE W

The ROSECRANS AVE W bridge in Los Angeles, California carries ROSECRANS AVE W over LOS ANGELES RIV. It was built in 1951, making it 75 years old today. It was last reconstructed in 1972, extending its service life. The structure is built primarily of concrete and spans 8 sections, stretching 185.1 meters (607 feet) end to end. Daily traffic averages 13,699 vehicles, placing it in the heavily-trafficked tier of California bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range.

How ROSECRANS AVE W compares

▼ 5.2
Load rating vs California average (32.1 t; 25,538 of 25,848 rated)
3,547
Bridges in Los Angeles · 120 in Poor condition

Age against the county: built in 1951, earlier than 3,038 of Los Angeles's 3,547 bridges with a recorded construction year (86%), against a county median build year of 1965. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

ROSECRANS AVE W 26.9 t
California average (25,538 of 25,848 rated) 32.1 t

Live comparison across California bridges with a recorded inventory load rating (25,538 of 25,848 rated).

ROSECRANS AVE W vs every rated California bridge

Inventory load rating (metric tons), FHWA NBI, this state

27 Top 74% higher than 26% of 25,538 bridges

rated California bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
26.9 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Los Angeles inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 3,547 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1951
Last Reconstructed
1972
Material
Concrete
Number of Spans
8
Structure Length
185.1 m (607 ft)
Deck Width
11.8 m (39 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
13,699 vehicles/day
Structure Number
53C0190L

Condition Analysis

  • The deck (driving surface) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) rates good at 7/9, with no significant deterioration on file.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether ROSECRANS AVE W is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare ROSECRANS AVE W against other structures in Los Angeles and across California. California bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for ROSECRANS AVE W?

ROSECRANS AVE W in Los Angeles, California has a deck rating of 5/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is ROSECRANS AVE W inspected?

ROSECRANS AVE W's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 13,699 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. ROSECRANS AVE W is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for ROSECRANS AVE W?

ROSECRANS AVE W has an NBI inventory load rating of 26.9 metric tons.

Who is responsible for maintaining ROSECRANS AVE W?

ROSECRANS AVE W is owned and maintained by City/Municipal Highway Agency.

How old is ROSECRANS AVE W and does age affect safety?

ROSECRANS AVE W was built in 1951, making it 75 years old and last reconstructed in 1972.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.