FHWA NBI 2024 Inspection record Public-domain dataset

N15-BAKER BL OFFRP

Carrying N15-BAKER BL OFFRP over INTERSTATE 15

08-SBD-015-R135.81, San Bernardino, California

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
50 t Inventory load rating Higher than 94% of rated California bridges

N15-BAKER BL OFFRP in San Bernardino, California sits above 94% of rated California bridges on inventory load rating (50 t), while its 1965 build year is earlier than 68% of San Bernardino's recorded-year cohort (1,422 bridges).

N15-BAKER BL OFFRP in San Bernardino, California is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1965, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure CA:54 0609S

INTERSTATE-ERA · STEEL · LONG-SPAN-RUN · SUB-LED · ARTERIAL-ADT · HEAVY-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • LONG-SPAN-RUN 4 spans
  • SUB-LED Substructure-led
  • ARTERIAL-ADT Arterial ADT
  • HEAVY-LOAD Heavy load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: N15-BAKER BL OFFRP

The N15-BAKER BL OFFRP bridge in San Bernardino, California carries N15-BAKER BL OFFRP over INTERSTATE 15. It was built in 1965, making it 61 years old today. The structure is built primarily of steel and spans 4 sections, stretching 93.6 meters (307 feet) end to end. Daily traffic averages 4,500 vehicles, placing it in the moderately-trafficked tier of California bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 5/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How N15-BAKER BL OFFRP compares

▲ 17.5
Load rating vs California average (32.1 t; 25,538 of 25,848 rated)
1,422
Bridges in San Bernardino · 85 in Poor condition

Age against the county: built in 1965, earlier than 964 of San Bernardino's 1,422 bridges with a recorded construction year (68%), against a county median build year of 1971. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

N15-BAKER BL OFFRP 49.6 t
California average (25,538 of 25,848 rated) 32.1 t

Live comparison across California bridges with a recorded inventory load rating (25,538 of 25,848 rated).

N15-BAKER BL OFFRP vs every rated California bridge

Inventory load rating (metric tons), FHWA NBI, this state

50 Top 6% higher than 94% of 25,538 bridges

rated California bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
49.6 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

San Bernardino inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 1,422 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1965
Material
Steel
Number of Spans
4
Structure Length
93.6 m (307 ft)
Deck Width
10.4 m (34 ft)
Owner
State Highway Agency
Avg Daily Traffic
4,500 vehicles/day
Structure Number
54 0609S

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) rates good at 7/9, with no significant deterioration on file.
  • At 5/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

This page shows what the last federal inspection recorded, not whether N15-BAKER BL OFFRP is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare N15-BAKER BL OFFRP against other structures in San Bernardino and across California. California bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for N15-BAKER BL OFFRP?

N15-BAKER BL OFFRP in San Bernardino, California has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is N15-BAKER BL OFFRP inspected?

N15-BAKER BL OFFRP's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 4,500 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. N15-BAKER BL OFFRP is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for N15-BAKER BL OFFRP?

N15-BAKER BL OFFRP has an NBI inventory load rating of 49.6 metric tons.

Who is responsible for maintaining N15-BAKER BL OFFRP?

N15-BAKER BL OFFRP is owned and maintained by State Highway Agency.

How old is N15-BAKER BL OFFRP and does age affect safety?

N15-BAKER BL OFFRP was built in 1965, making it 61 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.