FHWA NBI 2024 Inspection record Public-domain dataset

W8-S5&CDR CONNECT

Carrying W8-S5&CDR CONNECT over I-8 I-5 RAMPS BNSF AMTRA

11-SD-008-L2.34-SD, San Diego, California

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
41 t Inventory load rating Higher than 87% of rated California bridges

W8-S5&CDR CONNECT in San Diego, California sits above 87% of rated California bridges on inventory load rating (41 t), while its 1969 build year is earlier than 64% of San Diego's recorded-year cohort (1,632 bridges).

W8-S5&CDR CONNECT in San Diego, California is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1969, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure CA:57 0551F

INTERSTATE-ERA · CONCRETE · LONG-SPAN-RUN · DECK-LED · HEAVY-ADT · HEAVY-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • CONCRETE Concrete
  • LONG-SPAN-RUN 17 spans
  • DECK-LED Deck-led
  • HEAVY-ADT Heavy ADT
  • HEAVY-LOAD Heavy load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: W8-S5&CDR CONNECT

The W8-S5&CDR CONNECT bridge in San Diego, California carries W8-S5&CDR CONNECT over I-8 I-5 RAMPS BNSF AMTRA. It was built in 1969, making it 57 years old today. The structure is built primarily of concrete continuous and spans 17 sections, stretching 553.8 meters (1817 feet) end to end. Daily traffic averages 31,500 vehicles, placing it in the heavily-trafficked tier of California bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in fair condition. All reported major components score above the Poor range.

How W8-S5&CDR CONNECT compares

▲ 8.7
Load rating vs California average (32.1 t; 25,538 of 25,848 rated)
1,632
Bridges in San Diego · 50 in Poor condition

Age against the county: built in 1969, earlier than 1,050 of San Diego's 1,632 bridges with a recorded construction year (64%), against a county median build year of 1974. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

W8-S5&CDR CONNECT 40.8 t
California average (25,538 of 25,848 rated) 32.1 t

Live comparison across California bridges with a recorded inventory load rating (25,538 of 25,848 rated).

W8-S5&CDR CONNECT vs every rated California bridge

Inventory load rating (metric tons), FHWA NBI, this state

41 Top 13% higher than 87% of 25,538 bridges

rated California bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
40.8 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

San Diego inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 1,632 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1969
Material
Concrete Continuous
Number of Spans
17
Structure Length
553.8 m (1817 ft)
Deck Width
15.3 m (50 ft)
Owner
State Highway Agency
Avg Daily Traffic
31,500 vehicles/day
Structure Number
57 0551F

Condition Analysis

  • At 5/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether W8-S5&CDR CONNECT is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare W8-S5&CDR CONNECT against other structures in San Diego and across California. California bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for W8-S5&CDR CONNECT?

W8-S5&CDR CONNECT in San Diego, California has a deck rating of 5/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is W8-S5&CDR CONNECT inspected?

W8-S5&CDR CONNECT's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 31,500 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. W8-S5&CDR CONNECT is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for W8-S5&CDR CONNECT?

W8-S5&CDR CONNECT has an NBI inventory load rating of 40.8 metric tons.

Who is responsible for maintaining W8-S5&CDR CONNECT?

W8-S5&CDR CONNECT is owned and maintained by State Highway Agency.

How old is W8-S5&CDR CONNECT and does age affect safety?

W8-S5&CDR CONNECT was built in 1969, making it 57 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.