FHWA NBI 2024 Inspection record Public-domain dataset

IRR BIA RTE 204

Carrying IRR BIA RTE 204 over NAVAJO CANYON

23.3 KM SE OF TOWAOC CO, Montezuma, Colorado

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
25 t Inventory load rating Lower than 82% of rated Colorado bridges

IRR BIA RTE 204 in Montezuma, Colorado sits above 18% of rated Colorado bridges on inventory load rating (25 t), while its 1975 build year is earlier than 52% of Montezuma's recorded-year cohort (61 bridges).

IRR BIA RTE 204 in Montezuma, Colorado is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1975, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure CO:00000000000M607

INTERSTATE-ERA · CONCRETE · MULTI-SPAN · TIED-CTRL · LOCAL-ADT · STANDARD-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • CONCRETE Concrete
  • MULTI-SPAN 3 spans
  • TIED-CTRL Tied control
  • LOCAL-ADT Local ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: IRR BIA RTE 204

The IRR BIA RTE 204 bridge in Montezuma, Colorado carries IRR BIA RTE 204 over NAVAJO CANYON. It was built in 1975, making it 51 years old today. The structure is built primarily of concrete continuous and spans 3 sections, stretching 20.4 meters (67 feet) end to end. Daily traffic averages 100 vehicles, placing it in the lower-traffic tier of Colorado bridges. It is owned and maintained by Bureau of Indian Affairs.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 7/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How IRR BIA RTE 204 compares

▼ 12.3
Load rating vs Colorado average (36.8 t; 8,962 of 8,965 rated)
61
Bridges in Montezuma · 5 in Poor condition

Age against the county: built in 1975, earlier than 32 of Montezuma's 61 bridges with a recorded construction year (52%), against a county median build year of 1977. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

IRR BIA RTE 204 24.5 t
Colorado average (8,962 of 8,965 rated) 36.8 t

Live comparison across Colorado bridges with a recorded inventory load rating (8,962 of 8,965 rated).

IRR BIA RTE 204 vs every rated Colorado bridge

Inventory load rating (metric tons), FHWA NBI, this state

25 Top 82% higher than 18% of 8,962 bridges

rated Colorado bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
24.5 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Montezuma inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 61 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1975
Material
Concrete Continuous
Number of Spans
3
Structure Length
20.4 m (67 ft)
Deck Width
10.0 m (33 ft)
Owner
Bureau of Indian Affairs
Avg Daily Traffic
100 vehicles/day
Structure Number
00000000000M607

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether IRR BIA RTE 204 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare IRR BIA RTE 204 against other structures in Montezuma and across Colorado. Colorado bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for IRR BIA RTE 204?

IRR BIA RTE 204 in Montezuma, Colorado has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is IRR BIA RTE 204 inspected?

IRR BIA RTE 204's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 100 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. IRR BIA RTE 204 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for IRR BIA RTE 204?

IRR BIA RTE 204 has an NBI inventory load rating of 24.5 metric tons.

Who is responsible for maintaining IRR BIA RTE 204?

IRR BIA RTE 204 is owned and maintained by Bureau of Indian Affairs.

How old is IRR BIA RTE 204 and does age affect safety?

IRR BIA RTE 204 was built in 1975, making it 51 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.