FHWA NBI 2024 Inspection record Public-domain dataset

GALLEY ROAD

Carrying GALLEY ROAD over SAND CREEK

0.25 MI W OF POWERS BLVD., El Paso, Colorado

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
36 t Inventory load rating Higher than 64% of rated Colorado bridges

GALLEY ROAD in El Paso, Colorado sits above 64% of rated Colorado bridges on inventory load rating (36 t), while its 1993 build year is earlier than 40% of El Paso's recorded-year cohort (686 bridges).

GALLEY ROAD in El Paso, Colorado is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1993, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure CO:CSG-L.80-09.61

LATE-CENTURY · PRESTRESS · MULTI-SPAN · TIED-CTRL · HEAVY-ADT · STANDARD-LOAD · CAT-FAIR

  • LATE-CENTURY 1980–1999
  • PRESTRESS Prestressed concrete
  • MULTI-SPAN 2 spans
  • TIED-CTRL Tied control
  • HEAVY-ADT Heavy ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: GALLEY ROAD

The GALLEY ROAD bridge in El Paso, Colorado carries GALLEY ROAD over SAND CREEK. It was built in 1993, making it 33 years old today. The structure is built primarily of prestressed concrete continuous and spans 2 sections, stretching 47.6 meters (156 feet) end to end. Daily traffic averages 16,074 vehicles, placing it in the heavily-trafficked tier of Colorado bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range.

How GALLEY ROAD compares

▼ 0.7
Load rating vs Colorado average (36.8 t; 8,962 of 8,965 rated)
686
Bridges in El Paso · 22 in Poor condition

Age against the county: built in 1993, earlier than 273 of El Paso's 686 bridges with a recorded construction year (40%), against a county median build year of 1988. This is one of the newer structures in its county.

GALLEY ROAD 36.1 t
Colorado average (8,962 of 8,965 rated) 36.8 t

Live comparison across Colorado bridges with a recorded inventory load rating (8,962 of 8,965 rated).

GALLEY ROAD vs every rated Colorado bridge

Inventory load rating (metric tons), FHWA NBI, this state

36 Top 36% higher than 64% of 8,962 bridges

rated Colorado bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
36.1 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

El Paso inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 686 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1993
Material
Prestressed Concrete Continuous
Number of Spans
2
Structure Length
47.6 m (156 ft)
Deck Width
24.5 m (80 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
16,074 vehicles/day
Structure Number
CSG-L.80-09.61

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) rates fair at 6/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether GALLEY ROAD is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare GALLEY ROAD against other structures in El Paso and across Colorado. Colorado bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for GALLEY ROAD?

GALLEY ROAD in El Paso, Colorado has a deck rating of 7/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is GALLEY ROAD inspected?

GALLEY ROAD's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 16,074 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. GALLEY ROAD is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for GALLEY ROAD?

GALLEY ROAD has an NBI inventory load rating of 36.1 metric tons.

Who is responsible for maintaining GALLEY ROAD?

GALLEY ROAD is owned and maintained by City/Municipal Highway Agency.

How old is GALLEY ROAD and does age affect safety?

GALLEY ROAD was built in 1993, making it 33 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.