FHWA NBI 2024 Inspection record Public-domain dataset

WB 6TH AVE

Carrying WB 6TH AVE over RR AND LIPAN STREET

0.35 MI EAST OF I25, Denver, Colorado

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
25 t Inventory load rating Lower than 80% of rated Colorado bridges

WB 6TH AVE in Denver, Colorado sits above 20% of rated Colorado bridges on inventory load rating (25 t), while its 1958 build year is earlier than 93% of Denver's recorded-year cohort (458 bridges).

WB 6TH AVE in Denver, Colorado is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1958, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure CO:D-03-V-160

INTERSTATE-ERA · STEEL · LONG-SPAN-RUN · SUB-LED · HEAVY-ADT · STANDARD-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • LONG-SPAN-RUN 19 spans
  • SUB-LED Substructure-led
  • HEAVY-ADT Heavy ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: WB 6TH AVE

The WB 6TH AVE bridge in Denver, Colorado carries WB 6TH AVE over RR AND LIPAN STREET. It was built in 1958, making it 68 years old today. It was last reconstructed in 2008, extending its service life. The structure is built primarily of steel continuous and spans 19 sections, stretching 409.9 meters (1345 feet) end to end. Daily traffic averages 31,795 vehicles, placing it in the heavily-trafficked tier of Colorado bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 7/9, substructure at 5/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range.

How WB 6TH AVE compares

▼ 11.5
Load rating vs Colorado average (36.8 t; 8,962 of 8,965 rated)
458
Bridges in Denver · 8 in Poor condition

Age against the county: built in 1958, earlier than 425 of Denver's 458 bridges with a recorded construction year (93%), against a county median build year of 1993. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

WB 6TH AVE 25.3 t
Colorado average (8,962 of 8,965 rated) 36.8 t

Live comparison across Colorado bridges with a recorded inventory load rating (8,962 of 8,965 rated).

WB 6TH AVE vs every rated Colorado bridge

Inventory load rating (metric tons), FHWA NBI, this state

25 Top 80% higher than 20% of 8,962 bridges

rated Colorado bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
25.3 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Denver inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 458 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1958
Last Reconstructed
2008
Material
Steel Continuous
Number of Spans
19
Structure Length
409.9 m (1345 ft)
Deck Width
11.1 m (36 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
31,795 vehicles/day
Structure Number
D-03-V-160

Condition Analysis

  • The deck (driving surface) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether WB 6TH AVE is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare WB 6TH AVE against other structures in Denver and across Colorado. Colorado bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for WB 6TH AVE?

WB 6TH AVE in Denver, Colorado has a deck rating of 6/9, superstructure rating of 7/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is WB 6TH AVE inspected?

WB 6TH AVE's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 31,795 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. WB 6TH AVE is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for WB 6TH AVE?

WB 6TH AVE has an NBI inventory load rating of 25.3 metric tons.

Who is responsible for maintaining WB 6TH AVE?

WB 6TH AVE is owned and maintained by City/Municipal Highway Agency.

How old is WB 6TH AVE and does age affect safety?

WB 6TH AVE was built in 1958, making it 68 years old and last reconstructed in 2008.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.