FHWA NBI 2024 Inspection record Public-domain dataset

ALLEY

Carrying ALLEY over EAST HARVARD GULCH

BTWN STEELE AND ADAMS, Denver, Colorado

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
29 t Inventory load rating Lower than 70% of rated Colorado bridges

ALLEY in Denver, Colorado sits above 30% of rated Colorado bridges on inventory load rating (29 t), while its 1967 build year is earlier than 82% of Denver's recorded-year cohort (458 bridges).

ALLEY in Denver, Colorado is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1967, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure CO:D-13-HGE-230

INTERSTATE-ERA · CONCRETE · MULTI-SPAN · SUB-LED · LOCAL-ADT · STANDARD-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • CONCRETE Concrete
  • MULTI-SPAN 2 spans
  • SUB-LED Substructure-led
  • LOCAL-ADT Local ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: ALLEY

The ALLEY bridge in Denver, Colorado carries ALLEY over EAST HARVARD GULCH. It was built in 1967, making it 59 years old today. The structure is built primarily of concrete continuous and spans 2 sections, stretching 14.5 meters (48 feet) end to end. Daily traffic averages 75 vehicles, placing it in the lower-traffic tier of Colorado bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 5/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How ALLEY compares

▼ 7.7
Load rating vs Colorado average (36.8 t; 8,962 of 8,965 rated)
458
Bridges in Denver · 8 in Poor condition

Age against the county: built in 1967, earlier than 376 of Denver's 458 bridges with a recorded construction year (82%), against a county median build year of 1993. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

ALLEY 29.1 t
Colorado average (8,962 of 8,965 rated) 36.8 t

Live comparison across Colorado bridges with a recorded inventory load rating (8,962 of 8,965 rated).

ALLEY vs every rated Colorado bridge

Inventory load rating (metric tons), FHWA NBI, this state

29 Top 70% higher than 30% of 8,962 bridges

rated Colorado bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
29.1 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Denver inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 458 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1967
Material
Concrete Continuous
Number of Spans
2
Structure Length
14.5 m (48 ft)
Deck Width
6.0 m (20 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
75 vehicles/day
Structure Number
D-13-HGE-230

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) rates fair at 5/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether ALLEY is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare ALLEY against other structures in Denver and across Colorado. Colorado bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for ALLEY?

ALLEY in Denver, Colorado has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is ALLEY inspected?

ALLEY's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 75 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. ALLEY is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for ALLEY?

ALLEY has an NBI inventory load rating of 29.1 metric tons.

Who is responsible for maintaining ALLEY?

ALLEY is owned and maintained by City/Municipal Highway Agency.

How old is ALLEY and does age affect safety?

ALLEY was built in 1967, making it 59 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.