FHWA NBI 2024 Inspection record Public-domain dataset

CENTENNIAL PARKWAY

Carrying CENTENNIAL PARKWAY over RIFLE CREEK

.4 MI WEST OF RR AVE, Garfield, Colorado

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
25 t Inventory load rating Lower than 81% of rated Colorado bridges

CENTENNIAL PARKWAY in Garfield, Colorado sits above 19% of rated Colorado bridges on inventory load rating (25 t), while its 1954 build year is earlier than 91% of Garfield's recorded-year cohort (167 bridges).

CENTENNIAL PARKWAY in Garfield, Colorado is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1954, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure CO:F-05-C

INTERSTATE-ERA · STEEL · MULTI-SPAN · SUPER-LED · ARTERIAL-ADT · STANDARD-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • MULTI-SPAN 3 spans
  • SUPER-LED Superstructure-led
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: CENTENNIAL PARKWAY

The CENTENNIAL PARKWAY bridge in Garfield, Colorado carries CENTENNIAL PARKWAY over RIFLE CREEK. It was built in 1954, making it 72 years old today. The structure is built primarily of steel continuous and spans 3 sections, stretching 48.6 meters (159 feet) end to end. Daily traffic averages 5,007 vehicles, placing it in the moderately-trafficked tier of Colorado bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 8/9, superstructure at 5/9, substructure at 7/9. The weakest component sits in fair condition. All reported major components score above the Poor range.

How CENTENNIAL PARKWAY compares

▼ 11.9
Load rating vs Colorado average (36.8 t; 8,962 of 8,965 rated)
167
Bridges in Garfield · 2 in Poor condition

Age against the county: built in 1954, earlier than 152 of Garfield's 167 bridges with a recorded construction year (91%), against a county median build year of 1982. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

CENTENNIAL PARKWAY 24.9 t
Colorado average (8,962 of 8,965 rated) 36.8 t

Live comparison across Colorado bridges with a recorded inventory load rating (8,962 of 8,965 rated).

CENTENNIAL PARKWAY vs every rated Colorado bridge

Inventory load rating (metric tons), FHWA NBI, this state

25 Top 81% higher than 19% of 8,962 bridges

rated Colorado bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
8/9
Good (7–9)
Superstructure
5/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
24.9 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Garfield inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 167 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1954
Material
Steel Continuous
Number of Spans
3
Structure Length
48.6 m (159 ft)
Deck Width
10.7 m (35 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
5,007 vehicles/day
Structure Number
F-05-C

Condition Analysis

  • At 8/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether CENTENNIAL PARKWAY is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare CENTENNIAL PARKWAY against other structures in Garfield and across Colorado. Colorado bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for CENTENNIAL PARKWAY?

CENTENNIAL PARKWAY in Garfield, Colorado has a deck rating of 8/9, superstructure rating of 5/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is CENTENNIAL PARKWAY inspected?

CENTENNIAL PARKWAY's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 5,007 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. CENTENNIAL PARKWAY is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for CENTENNIAL PARKWAY?

CENTENNIAL PARKWAY has an NBI inventory load rating of 24.9 metric tons.

Who is responsible for maintaining CENTENNIAL PARKWAY?

CENTENNIAL PARKWAY is owned and maintained by City/Municipal Highway Agency.

How old is CENTENNIAL PARKWAY and does age affect safety?

CENTENNIAL PARKWAY was built in 1954, making it 72 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.