FHWA NBI 2024 Inspection record Public-domain dataset

PERRY STREET

Carrying PERRY STREET over US 6 ML

IN DENVER, Denver, Colorado

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
18 t Inventory load rating Lower than 93% of rated Colorado bridges

PERRY STREET in Denver, Colorado sits above 7% of rated Colorado bridges on inventory load rating (18 t), while its 1964 build year is earlier than 90% of Denver's recorded-year cohort (458 bridges).

PERRY STREET in Denver, Colorado is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1964, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure CO:F-16-GG

INTERSTATE-ERA · STEEL · SINGLE-SPAN · DECK-LED · ARTERIAL-ADT · LIGHT-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • SINGLE-SPAN Single span
  • DECK-LED Deck-led
  • ARTERIAL-ADT Arterial ADT
  • LIGHT-LOAD Light load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: PERRY STREET

The PERRY STREET bridge in Denver, Colorado carries PERRY STREET over US 6 ML. It was built in 1964, making it 62 years old today. The structure is built primarily of steel and spans 1 section, stretching 27.7 meters (91 feet) end to end. Daily traffic averages 6,876 vehicles, placing it in the moderately-trafficked tier of Colorado bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 5/9, substructure at 5/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order.

How PERRY STREET compares

▼ 18.7
Load rating vs Colorado average (36.8 t; 8,962 of 8,965 rated)
458
Bridges in Denver · 8 in Poor condition

Age against the county: built in 1964, earlier than 412 of Denver's 458 bridges with a recorded construction year (90%), against a county median build year of 1993. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

PERRY STREET 18.1 t
Colorado average (8,962 of 8,965 rated) 36.8 t

Live comparison across Colorado bridges with a recorded inventory load rating (8,962 of 8,965 rated).

PERRY STREET vs every rated Colorado bridge

Inventory load rating (metric tons), FHWA NBI, this state

18 Top 93% higher than 7% of 8,962 bridges

rated Colorado bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
5/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
18.1 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Denver inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 458 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1964
Material
Steel
Number of Spans
1
Structure Length
27.7 m (91 ft)
Deck Width
17.7 m (58 ft)
Owner
State Highway Agency
Avg Daily Traffic
6,876 vehicles/day
Structure Number
F-16-GG

Condition Analysis

  • At 4/9, the deck (driving surface) is in poor shape, with advanced wear on file for this vintage.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) rates fair at 5/9, minor deterioration that routine maintenance should address.

How to read this record

PERRY STREET is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare PERRY STREET against other structures in Denver and across Colorado. Colorado bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for PERRY STREET?

PERRY STREET in Denver, Colorado has a deck rating of 4/9, superstructure rating of 5/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is PERRY STREET inspected?

PERRY STREET's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 6,876 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. PERRY STREET is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for PERRY STREET?

PERRY STREET has an NBI inventory load rating of 18.1 metric tons.

Who is responsible for maintaining PERRY STREET?

PERRY STREET is owned and maintained by State Highway Agency.

How old is PERRY STREET and does age affect safety?

PERRY STREET was built in 1964, making it 62 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.