Bridge Snapshot: WYO 116 S

The WYO 116 S bridge in Weston, Wyoming carries WYO 116 S over BNSF Railway. It was built in 1980, making it 46 years old today. The structure is built primarily of steel continuous and spans 3 sections, stretching 59.4 meters (195 feet) end to end. Daily traffic averages 514 vehicles, placing it in the lower-traffic tier of Wyoming bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 7/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 30.8 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How WYO 116 S compares

▼ 2.7
Load rating vs Wyoming average (33.5 t)
Bottom 31%
Lower load rating than 69% of Wyoming bridges
43
Bridges in Weston · 4 in Poor condition
WYO 116 S 30.8 t
Wyoming average 33.5 t

Live comparison across Wyoming.

Historical Sufficiency Rating

PlainBridge-computed
98.4 / 100 - historical 80–100 band
Structural adequacy /55
54.3
Serviceability /30
30.0
Essentiality /15
14.1
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
30.8 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1980
Material
Steel Continuous
Number of Spans
3
Structure Length
59.4 m (195 ft)
Deck Width
11.8 m (39 ft)
Owner
State Highway Agency
Avg Daily Traffic
514 vehicles/day
Structure Number
DGD

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether WYO 116 S is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare WYO 116 S against other structures in Weston and across Wyoming. Wyoming bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for WYO 116 S?

WYO 116 S in Weston, Wyoming has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is WYO 116 S inspected?

WYO 116 S's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 514 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. WYO 116 S is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for WYO 116 S?

WYO 116 S has an NBI inventory load rating of 30.8 metric tons.

Who is responsible for maintaining WYO 116 S?

WYO 116 S is owned and maintained by State Highway Agency.

How old is WYO 116 S and does age affect safety?

WYO 116 S was built in 1980, making it 46 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.