FHWA NBI 2024 Inspection record Public-domain dataset

WYO 120

Carrying WYO 120 over Cody Canal

Thermopolis - Cody, Park, Wyoming

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
35 t Inventory load rating

Bridge Snapshot: WYO 120

The WYO 120 bridge in Park, Wyoming carries WYO 120 over Cody Canal. It was built in 1979, making it 47 years old today. The structure is built primarily of steel and spans 1 section, stretching 18.0 meters (59 feet) end to end. Daily traffic averages 2,654 vehicles, placing it in the moderately-trafficked tier of Wyoming bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 34.5 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How WYO 120 compares

▲ 1.0
Load rating vs Wyoming average (33.5 t)
Top 33%
Higher load rating than 67% of Wyoming bridges
187
Bridges in Park · 8 in Poor condition
WYO 120 34.5 t
Wyoming average 33.5 t

Live comparison across Wyoming.

Historical Sufficiency Rating

PlainBridge-computed
90.8 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
29.0
Essentiality /15
6.9
Special reductions
−0.1

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
34.5 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1979
Material
Steel
Number of Spans
1
Structure Length
18.0 m (59 ft)
Deck Width
11.8 m (39 ft)
Owner
State Highway Agency
Avg Daily Traffic
2,654 vehicles/day
Structure Number
DIW

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether WYO 120 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare WYO 120 against other structures in Park and across Wyoming. Wyoming bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for WYO 120?

WYO 120 in Park, Wyoming has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is WYO 120 inspected?

WYO 120's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 2,654 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. WYO 120 is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for WYO 120?

WYO 120 has an NBI inventory load rating of 34.5 metric tons.

Who is responsible for maintaining WYO 120?

WYO 120 is owned and maintained by State Highway Agency.

How old is WYO 120 and does age affect safety?

WYO 120 was built in 1979, making it 47 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.