FHWA NBI 2024 Inspection record Public-domain dataset

US 30 / I-80 Bus

Carrying US 30 / I-80 Bus over Spring Creek

Laramie - Grand Ave, Albany, Wyoming

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
58 t Inventory load rating

Bridge Snapshot: US 30 / I-80 Bus

The US 30 / I-80 Bus bridge in Albany, Wyoming carries US 30 / I-80 Bus over Spring Creek. It was built in 1981, making it 45 years old today. The structure is built primarily of steel and spans 1 section, stretching 18.3 meters (60 feet) end to end. Daily traffic averages 14,742 vehicles, placing it in the heavily-trafficked tier of Wyoming bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 58.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How US 30 / I-80 Bus compares

▲ 24.6
Load rating vs Wyoming average (33.5 t)
Top 3%
Higher load rating than 97% of Wyoming bridges
124
Bridges in Albany · 1 in Poor condition
US 30 / I-80 Bus 58.1 t
Wyoming average 33.5 t

Live comparison across Wyoming.

Historical Sufficiency Rating

PlainBridge-computed
79.4 / 100 - historical 50–79.9 band
Structural adequacy /55
55.0
Serviceability /30
14.0
Essentiality /15
12.4
Special reductions
−2.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
58.1 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1981
Material
Steel
Number of Spans
1
Structure Length
18.3 m (60 ft)
Deck Width
25.0 m (82 ft)
Owner
State Highway Agency
Avg Daily Traffic
14,742 vehicles/day
Structure Number
DLN

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether US 30 / I-80 Bus is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare US 30 / I-80 Bus against other structures in Albany and across Wyoming. Wyoming bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for US 30 / I-80 Bus?

US 30 / I-80 Bus in Albany, Wyoming has a deck rating of 6/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is US 30 / I-80 Bus inspected?

US 30 / I-80 Bus's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 14,742 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. US 30 / I-80 Bus is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for US 30 / I-80 Bus?

US 30 / I-80 Bus has an NBI inventory load rating of 58.1 metric tons.

Who is responsible for maintaining US 30 / I-80 Bus?

US 30 / I-80 Bus is owned and maintained by State Highway Agency.

How old is US 30 / I-80 Bus and does age affect safety?

US 30 / I-80 Bus was built in 1981, making it 45 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.