FHWA NBI 2024 Inspection record Public-domain dataset

US27 SR20

Carrying US27 SR20 over Franklin Blvd

0.2mi. East of St.Capitol, Leon, Florida

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
22 t Inventory load rating Lower than 93% of rated Florida bridges

US27 SR20 in Leon, Florida sits above 7% of rated Florida bridges on inventory load rating (22 t), while its 1958 build year is earlier than 84% of Leon's recorded-year cohort (165 bridges).

US27 SR20 in Leon, Florida is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1958, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure FL:550064

INTERSTATE-ERA · STEEL · LONG-SPAN-RUN · DECK-LED · HEAVY-ADT · STANDARD-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • LONG-SPAN-RUN 6 spans
  • DECK-LED Deck-led
  • HEAVY-ADT Heavy ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: US27 SR20

The US27 SR20 bridge in Leon, Florida carries US27 SR20 over Franklin Blvd. It was built in 1958, making it 68 years old today. It was last reconstructed in 1974, extending its service life. The structure is built primarily of steel continuous and spans 6 sections, stretching 123.7 meters (406 feet) end to end. Daily traffic averages 13,750 vehicles, placing it in the heavily-trafficked tier of Florida bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How US27 SR20 compares

▼ 16.7
Load rating vs Florida average (38.7 t; 13,032 of 13,036 rated)
165
Bridges in Leon · 7 in Poor condition

Age against the county: built in 1958, earlier than 139 of Leon's 165 bridges with a recorded construction year (84%), against a county median build year of 1975. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

US27 SR20 22.0 t
Florida average (13,032 of 13,036 rated) 38.7 t

Live comparison across Florida bridges with a recorded inventory load rating (13,032 of 13,036 rated).

US27 SR20 vs every rated Florida bridge

Inventory load rating (metric tons), FHWA NBI, this state

22 Top 93% higher than 7% of 13,032 bridges

rated Florida bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
22.0 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Leon inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 165 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1958
Last Reconstructed
1974
Material
Steel Continuous
Number of Spans
6
Structure Length
123.7 m (406 ft)
Deck Width
10.7 m (35 ft)
Owner
State Highway Agency
Avg Daily Traffic
13,750 vehicles/day
Structure Number
550064

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether US27 SR20 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare US27 SR20 against other structures in Leon and across Florida. Florida bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for US27 SR20?

US27 SR20 in Leon, Florida has a deck rating of 6/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is US27 SR20 inspected?

US27 SR20's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 13,750 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. US27 SR20 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for US27 SR20?

US27 SR20 has an NBI inventory load rating of 22.0 metric tons.

Who is responsible for maintaining US27 SR20?

US27 SR20 is owned and maintained by State Highway Agency.

How old is US27 SR20 and does age affect safety?

US27 SR20 was built in 1958, making it 68 years old and last reconstructed in 1974.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.