FHWA NBI 2024 Inspection record Public-domain dataset

Colechester Lane

Carrying Colechester Lane over College Waterway

0.4 Mi E of Palm Hbr Pkwy, Flagler, Florida

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Good
30 t Inventory load rating Lower than 77% of rated Florida bridges

Colechester Lane in Flagler, Florida sits above 23% of rated Florida bridges on inventory load rating (30 t), while its 1974 build year is earlier than 61% of Flagler's recorded-year cohort (105 bridges).

Colechester Lane in Flagler, Florida is rated Good in the FHWA's 2024 National Bridge Inventory. Built in 1974, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 7. The lowest applicable rating sets the federal condition category, so this Good result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure FL:734063

INTERSTATE-ERA · PRESTRESS · LONG-SPAN-RUN · TIED-CTRL · LOCAL-ADT · STANDARD-LOAD · CAT-GOOD

  • INTERSTATE-ERA 1950–1979
  • PRESTRESS Prestressed concrete
  • LONG-SPAN-RUN 5 spans
  • TIED-CTRL Tied control
  • LOCAL-ADT Local ADT
  • STANDARD-LOAD Standard load
  • CAT-GOOD Good

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: Colechester Lane

The Colechester Lane bridge in Flagler, Florida carries Colechester Lane over College Waterway. It was built in 1974, making it 52 years old today. It was last reconstructed in 2016, extending its service life. The structure is built primarily of prestressed concrete and spans 5 sections, stretching 49.0 meters (161 feet) end to end. Daily traffic averages 128 vehicles, placing it in the lower-traffic tier of Florida bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. None of this bridge's reported major components fall into the Poor condition range.

How Colechester Lane compares

▼ 8.3
Load rating vs Florida average (38.7 t; 13,032 of 13,036 rated)
105
Bridges in Flagler · 2 in Poor condition

Age against the county: built in 1974, earlier than 64 of Flagler's 105 bridges with a recorded construction year (61%), against a county median build year of 1980. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

Colechester Lane 30.4 t
Florida average (13,032 of 13,036 rated) 38.7 t

Live comparison across Florida bridges with a recorded inventory load rating (13,032 of 13,036 rated).

Colechester Lane vs every rated Florida bridge

Inventory load rating (metric tons), FHWA NBI, this state

30 Top 77% higher than 23% of 13,032 bridges

rated Florida bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
30.4 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Flagler inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 105 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1974
Last Reconstructed
2016
Material
Prestressed Concrete
Number of Spans
5
Structure Length
49.0 m (161 ft)
Deck Width
11.9 m (39 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
128 vehicles/day
Structure Number
734063

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) rates good at 7/9, with no significant deterioration on file.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether Colechester Lane is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare Colechester Lane against other structures in Flagler and across Florida. Florida bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for Colechester Lane?

Colechester Lane in Flagler, Florida has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is Colechester Lane inspected?

Colechester Lane's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 128 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. Colechester Lane is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for Colechester Lane?

Colechester Lane has an NBI inventory load rating of 30.4 metric tons.

Who is responsible for maintaining Colechester Lane?

Colechester Lane is owned and maintained by City/Municipal Highway Agency.

How old is Colechester Lane and does age affect safety?

Colechester Lane was built in 1974, making it 52 years old and last reconstructed in 2016.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.