FHWA NBI 2024 Inspection record Public-domain dataset

3rd Level Enplan B

Carrying 3rd Level Enplan B over 2nd Level Deplane B

S. Side of Terminal OIA, Orange, Florida

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
11 t Inventory load rating Lower than 99% of rated Florida bridges

3rd Level Enplan B in Orange, Florida sits above 1% of rated Florida bridges on inventory load rating (11 t), while its 1981 build year is earlier than 80% of Orange's recorded-year cohort (885 bridges).

3rd Level Enplan B in Orange, Florida is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1981, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure FL:755911

LATE-CENTURY · PRESTRESS · LONG-SPAN-RUN · DECK-LED · ARTERIAL-ADT · LIGHT-LOAD · CAT-FAIR

  • LATE-CENTURY 1980–1999
  • PRESTRESS Prestressed concrete
  • LONG-SPAN-RUN 44 spans
  • DECK-LED Deck-led
  • ARTERIAL-ADT Arterial ADT
  • LIGHT-LOAD Light load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: 3rd Level Enplan B

The 3rd Level Enplan B bridge in Orange, Florida carries 3rd Level Enplan B over 2nd Level Deplane B. It was built in 1981, making it 45 years old today. It was last reconstructed in 1990, extending its service life. The structure is built primarily of prestressed concrete and spans 44 sections, stretching 489.6 meters (1606 feet) end to end. Daily traffic averages 5,339 vehicles, placing it in the moderately-trafficked tier of Florida bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How 3rd Level Enplan B compares

▼ 27.9
Load rating vs Florida average (38.7 t; 13,032 of 13,036 rated)
885
Bridges in Orange · 1 in Poor condition

Age against the county: built in 1981, earlier than 705 of Orange's 885 bridges with a recorded construction year (80%), against a county median build year of 2001. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

3rd Level Enplan B 10.8 t
Florida average (13,032 of 13,036 rated) 38.7 t

Live comparison across Florida bridges with a recorded inventory load rating (13,032 of 13,036 rated).

3rd Level Enplan B vs every rated Florida bridge

Inventory load rating (metric tons), FHWA NBI, this state

11 Top 99% higher than 1% of 13,032 bridges

rated Florida bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
10.8 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Orange inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 885 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1981
Last Reconstructed
1990
Material
Prestressed Concrete
Number of Spans
44
Structure Length
489.6 m (1606 ft)
Deck Width
19.8 m (65 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
5,339 vehicles/day
Structure Number
755911

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether 3rd Level Enplan B is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare 3rd Level Enplan B against other structures in Orange and across Florida. Florida bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for 3rd Level Enplan B?

3rd Level Enplan B in Orange, Florida has a deck rating of 6/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is 3rd Level Enplan B inspected?

3rd Level Enplan B's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 5,339 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. 3rd Level Enplan B is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for 3rd Level Enplan B?

3rd Level Enplan B has an NBI inventory load rating of 10.8 metric tons.

Who is responsible for maintaining 3rd Level Enplan B?

3rd Level Enplan B is owned and maintained by City/Municipal Highway Agency.

How old is 3rd Level Enplan B and does age affect safety?

3rd Level Enplan B was built in 1981, making it 45 years old and last reconstructed in 1990.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.