FHWA NBI 2024 Inspection record Public-domain dataset

EAST HIGHTOWER TRL

Carrying EAST HIGHTOWER TRL over CSX RAILROAD

CITY OF SOCIAL CIRCLE, Walton, Georgia

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Good
45 t Inventory load rating Higher than 89% of rated Georgia bridges

EAST HIGHTOWER TRL in Walton, Georgia sits above 89% of rated Georgia bridges on inventory load rating (45 t), while its 1970 build year is earlier than 62% of Walton's recorded-year cohort (115 bridges).

EAST HIGHTOWER TRL in Walton, Georgia is rated Good in the FHWA's 2024 National Bridge Inventory. Built in 1970, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 7. The lowest applicable rating sets the federal condition category, so this Good result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure GA:000000029700430

INTERSTATE-ERA · STEEL · MULTI-SPAN · SUB-LED · ARTERIAL-ADT · HEAVY-LOAD · CAT-GOOD

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • MULTI-SPAN 3 spans
  • SUB-LED Substructure-led
  • ARTERIAL-ADT Arterial ADT
  • HEAVY-LOAD Heavy load
  • CAT-GOOD Good

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: EAST HIGHTOWER TRL

The EAST HIGHTOWER TRL bridge in Walton, Georgia carries EAST HIGHTOWER TRL over CSX RAILROAD. It was built in 1970, making it 56 years old today. It was last reconstructed in 2012, extending its service life. The structure is built primarily of steel and spans 3 sections, stretching 27.7 meters (91 feet) end to end. Daily traffic averages 6,410 vehicles, placing it in the moderately-trafficked tier of Georgia bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 8/9, superstructure at 8/9, substructure at 7/9. The weakest component sits in good condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How EAST HIGHTOWER TRL compares

▲ 11.8
Load rating vs Georgia average (33.5 t; 15,056 of 15,069 rated)
115
Bridges in Walton · 2 in Poor condition

Age against the county: built in 1970, earlier than 71 of Walton's 115 bridges with a recorded construction year (62%), against a county median build year of 1985. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

EAST HIGHTOWER TRL 45.3 t
Georgia average (15,056 of 15,069 rated) 33.5 t

Live comparison across Georgia bridges with a recorded inventory load rating (15,056 of 15,069 rated).

EAST HIGHTOWER TRL vs every rated Georgia bridge

Inventory load rating (metric tons), FHWA NBI, this state

45 Top 11% higher than 89% of 15,056 bridges

rated Georgia bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
8/9
Good (7–9)
Superstructure
8/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
45.3 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Walton inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 115 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1970
Last Reconstructed
2012
Material
Steel
Number of Spans
3
Structure Length
27.7 m (91 ft)
Deck Width
8.0 m (26 ft)
Owner
County Highway Agency
Avg Daily Traffic
6,410 vehicles/day
Structure Number
000000029700430

Condition Analysis

  • The deck (driving surface) is in good condition (8/9), showing no significant deterioration.
  • The superstructure (beams and supports above the deck) rates good at 8/9, with no significant deterioration on file.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether EAST HIGHTOWER TRL is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare EAST HIGHTOWER TRL against other structures in Walton and across Georgia. Georgia bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for EAST HIGHTOWER TRL?

EAST HIGHTOWER TRL in Walton, Georgia has a deck rating of 8/9, superstructure rating of 8/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is EAST HIGHTOWER TRL inspected?

EAST HIGHTOWER TRL's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 6,410 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. EAST HIGHTOWER TRL is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for EAST HIGHTOWER TRL?

EAST HIGHTOWER TRL has an NBI inventory load rating of 45.3 metric tons.

Who is responsible for maintaining EAST HIGHTOWER TRL?

EAST HIGHTOWER TRL is owned and maintained by County Highway Agency.

How old is EAST HIGHTOWER TRL and does age affect safety?

EAST HIGHTOWER TRL was built in 1970, making it 56 years old and last reconstructed in 2012.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.