90TH ST.
Carrying 90TH ST. over SMALL STREAM
092082901, Fayette, Iowa
Inventory: FHWA NBI 2024 · last ETL August 2026
FHWA NBI record, refreshed with each annual release.
90TH ST. in Fayette, Iowa sits above 56% of rated Iowa bridges on inventory load rating (33 t), while its 1990 build year is earlier than 34% of Fayette's recorded-year cohort (362 bridges).
90TH ST. in Fayette, Iowa is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1990, it carries 1 rated component on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.
NBI record plate
Structure IA:000000000150341
LATE-CENTURY · STEEL · MULTI-SPAN · CULVERT-LED · TRACE-ADT · STANDARD-LOAD · CAT-POOR
- LATE-CENTURY 1980–1999
- STEEL Steel
- MULTI-SPAN 2 spans
- CULVERT-LED Culvert-led
- TRACE-ADT Trace ADT
- STANDARD-LOAD Standard load
- CAT-POOR Poor
Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.
Bridge Snapshot: 90TH ST.
The 90TH ST. bridge in Fayette, Iowa carries 90TH ST. over SMALL STREAM. It was built in 1990, making it 36 years old today. The structure is built primarily of steel and spans 2 sections, stretching 7.0 meters (23 feet) end to end. Daily traffic averages 34 vehicles, placing it in the lower-traffic tier of Iowa bridges. It is owned and maintained by County Highway Agency.
The latest FHWA inspection records show culvert at 4/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules.
How 90TH ST. compares
Age against the county: built in 1990, earlier than 123 of Fayette's 362 bridges with a recorded construction year (34%), against a county median build year of 1979. This is one of the newer structures in its county.
Live comparison across Iowa bridges with a recorded inventory load rating (23,718 of 23,719 rated).
90TH ST. vs every rated Iowa bridge
Inventory load rating (metric tons), FHWA NBI, this state
33 Top 44% higher than 56% of 23,718 bridges
rated Iowa bridges, bucketed by value
Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.
Source FHWA National Bridge Inventory · August 2026
Condition Ratings
Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.
Fayette inventory by recorded NBI category
Exclusive Good/Fair/Poor bands across all 362 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.
Structural Details
- Year Built
- 1990
- Material
- Steel
- Number of Spans
- 2
- Structure Length
- 7.0 m (23 ft) 0
- Owner
- County Highway Agency
- Avg Daily Traffic
- 34 vehicles/day
- Structure Number
- 000000000150341
Location
Data Source
FHWA National Bridge Inventory (NBI).
FHWA NBI Program ↗How to read this record
90TH ST. is in the federal Poor condition category. That is a component-based result, not a closure order.
- NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
- Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
- Compare 90TH ST. against other structures in Fayette and across Iowa. Iowa bridges
- Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge
Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.
Frequently Asked Questions
What do the condition ratings mean for 90TH ST.?
90TH ST. in Fayette, Iowa on the FHWA's 0–9 scale.
How often is 90TH ST. inspected?
90TH ST.'s responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 34 vehicles per day.
What does “structurally deficient” mean in older bridge reports?
FHWA retired that reported status beginning with the 2018 archive. 90TH ST. is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.
What is the inventory load rating for 90TH ST.?
90TH ST. has an NBI inventory load rating of 32.7 metric tons.
Who is responsible for maintaining 90TH ST.?
90TH ST. is owned and maintained by County Highway Agency.
How old is 90TH ST. and does age affect safety?
90TH ST. was built in 1990, making it 36 years old.
Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.
Share this inspection record
Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.
Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.