FHWA NBI 2024 Inspection record Public-domain dataset

STC3710;SUMMER CMP

Carrying STC3710;SUMMER CMP over SQUAW CREEK

6.75 SW MARSING, Owyhee, Idaho

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Good
68 t Inventory load rating Higher than 97% of rated Idaho bridges

STC3710;SUMMER CMP in Owyhee, Idaho sits above 97% of rated Idaho bridges on inventory load rating (68 t), while its 1988 build year is earlier than 29% of Owyhee's recorded-year cohort (48 bridges).

STC3710;SUMMER CMP in Owyhee, Idaho is rated Good in the FHWA's 2024 National Bridge Inventory. Built in 1988, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 7. The lowest applicable rating sets the federal condition category, so this Good result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure ID:000000000019670

LATE-CENTURY · CONCRETE · SINGLE-SPAN · TIED-CTRL · LOCAL-ADT · HEAVY-LOAD · CAT-GOOD

  • LATE-CENTURY 1980–1999
  • CONCRETE Concrete
  • SINGLE-SPAN Single span
  • TIED-CTRL Tied control
  • LOCAL-ADT Local ADT
  • HEAVY-LOAD Heavy load
  • CAT-GOOD Good

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: STC3710;SUMMER CMP

The STC3710;SUMMER CMP bridge in Owyhee, Idaho carries STC3710;SUMMER CMP over SQUAW CREEK. It was built in 1988, making it 38 years old today. The structure is built primarily of concrete and spans 1 section, stretching 6.1 meters (20 feet) end to end. Daily traffic averages 100 vehicles, placing it in the lower-traffic tier of Idaho bridges. It is owned and maintained by Other Local Agencies.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. None of this bridge's reported major components fall into the Poor condition range.

How STC3710;SUMMER CMP compares

▲ 34.7
Load rating vs Idaho average (33.3 t; 4,574 of 4,616 rated)
48
Bridges in Owyhee · 4 in Poor condition

Age against the county: built in 1988, earlier than 14 of Owyhee's 48 bridges with a recorded construction year (29%), against a county median build year of 1974. This is one of the newer structures in its county.

STC3710;SUMMER CMP 68.0 t
Idaho average (4,574 of 4,616 rated) 33.3 t

Live comparison across Idaho bridges with a recorded inventory load rating (4,574 of 4,616 rated).

STC3710;SUMMER CMP vs every rated Idaho bridge

Inventory load rating (metric tons), FHWA NBI, this state

68 Top 3% higher than 97% of 4,574 bridges

rated Idaho bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
68.0 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Owyhee inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 48 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1988
Material
Concrete
Number of Spans
1
Structure Length
6.1 m (20 ft)
Deck Width
12.2 m (40 ft)
Owner
Other Local Agencies
Avg Daily Traffic
100 vehicles/day
Structure Number
000000000019670

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether STC3710;SUMMER CMP is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare STC3710;SUMMER CMP against other structures in Owyhee and across Idaho. Idaho bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for STC3710;SUMMER CMP?

STC3710;SUMMER CMP in Owyhee, Idaho has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is STC3710;SUMMER CMP inspected?

STC3710;SUMMER CMP's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 100 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. STC3710;SUMMER CMP is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for STC3710;SUMMER CMP?

STC3710;SUMMER CMP has an NBI inventory load rating of 68.0 metric tons.

Who is responsible for maintaining STC3710;SUMMER CMP?

STC3710;SUMMER CMP is owned and maintained by Other Local Agencies.

How old is STC3710;SUMMER CMP and does age affect safety?

STC3710;SUMMER CMP was built in 1988, making it 38 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.