FHWA NBI 2024 Inspection record Public-domain dataset

STC3892;INDIAN VLY

Carrying STC3892;INDIAN VLY over GRAYS CREEK

1.9N. 0.5W. INDIAN VALLEY, Adams, Idaho

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
23 t Inventory load rating Lower than 76% of rated Idaho bridges

STC3892;INDIAN VLY in Adams, Idaho sits above 24% of rated Idaho bridges on inventory load rating (23 t), while its 1930 build year is earlier than 90% of Adams's recorded-year cohort (87 bridges).

STC3892;INDIAN VLY in Adams, Idaho is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1930, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure ID:000000000020045

PRE-1950 · PRESTRESS · SINGLE-SPAN · SUB-LED · LOCAL-ADT · STANDARD-LOAD · CAT-FAIR

  • PRE-1950 Pre-1950
  • PRESTRESS Prestressed concrete
  • SINGLE-SPAN Single span
  • SUB-LED Substructure-led
  • LOCAL-ADT Local ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: STC3892;INDIAN VLY

The STC3892;INDIAN VLY bridge in Adams, Idaho carries STC3892;INDIAN VLY over GRAYS CREEK. It was built in 1930, making it 96 years old today. It was last reconstructed in 1965, extending its service life. The structure is built primarily of prestressed concrete and spans 1 section, stretching 8.2 meters (27 feet) end to end. Daily traffic averages 160 vehicles, placing it in the lower-traffic tier of Idaho bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 6/9. The weakest component sits in fair condition. All reported major components score above the Poor range.

How STC3892;INDIAN VLY compares

▼ 10.6
Load rating vs Idaho average (33.3 t; 4,574 of 4,616 rated)
87
Bridges in Adams · 9 in Poor condition

Age against the county: built in 1930, earlier than 78 of Adams's 87 bridges with a recorded construction year (90%), against a county median build year of 1973. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

STC3892;INDIAN VLY 22.7 t
Idaho average (4,574 of 4,616 rated) 33.3 t

Live comparison across Idaho bridges with a recorded inventory load rating (4,574 of 4,616 rated).

STC3892;INDIAN VLY vs every rated Idaho bridge

Inventory load rating (metric tons), FHWA NBI, this state

23 Top 76% higher than 24% of 4,574 bridges

rated Idaho bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
22.7 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Adams inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 87 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1930
Last Reconstructed
1965
Material
Prestressed Concrete
Number of Spans
1
Structure Length
8.2 m (27 ft)
Deck Width
8.6 m (28 ft)
Owner
County Highway Agency
Avg Daily Traffic
160 vehicles/day
Structure Number
000000000020045

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • At 6/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

This page shows what the last federal inspection recorded, not whether STC3892;INDIAN VLY is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare STC3892;INDIAN VLY against other structures in Adams and across Idaho. Idaho bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for STC3892;INDIAN VLY?

STC3892;INDIAN VLY in Adams, Idaho has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is STC3892;INDIAN VLY inspected?

STC3892;INDIAN VLY's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 160 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. STC3892;INDIAN VLY is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for STC3892;INDIAN VLY?

STC3892;INDIAN VLY has an NBI inventory load rating of 22.7 metric tons.

Who is responsible for maintaining STC3892;INDIAN VLY?

STC3892;INDIAN VLY is owned and maintained by County Highway Agency.

How old is STC3892;INDIAN VLY and does age affect safety?

STC3892;INDIAN VLY was built in 1930, making it 96 years old and last reconstructed in 1965.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.