FHWA NBI 2024 Inspection record Public-domain dataset

SMA 7733;KIMBALL A

Carrying SMA 7733;KIMBALL A over INDIAN CREEK

IN CALDWELL;S.KIMBALL AVE, Canyon, Idaho

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
37 t Inventory load rating Higher than 68% of rated Idaho bridges

SMA 7733;KIMBALL A in Canyon, Idaho sits above 68% of rated Idaho bridges on inventory load rating (37 t), while its 1933 build year is earlier than 99% of Canyon's recorded-year cohort (292 bridges).

SMA 7733;KIMBALL A in Canyon, Idaho is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1933, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure ID:000000000027610

PRE-1950 · CONCRETE · MULTI-SPAN · SUPER-LED · ARTERIAL-ADT · STANDARD-LOAD · CAT-POOR

  • PRE-1950 Pre-1950
  • CONCRETE Concrete
  • MULTI-SPAN 2 spans
  • SUPER-LED Superstructure-led
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: SMA 7733;KIMBALL A

The SMA 7733;KIMBALL A bridge in Canyon, Idaho carries SMA 7733;KIMBALL A over INDIAN CREEK. It was built in 1933, making it 93 years old today. It was last reconstructed in 2008, extending its service life. The structure is built primarily of concrete and spans 2 sections, stretching 11.9 meters (39 feet) end to end. Daily traffic averages 3,500 vehicles, placing it in the moderately-trafficked tier of Idaho bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 4/9, substructure at 5/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed.

How SMA 7733;KIMBALL A compares

▲ 3.9
Load rating vs Idaho average (33.3 t; 4,574 of 4,616 rated)
292
Bridges in Canyon · 8 in Poor condition

Age against the county: built in 1933, earlier than 288 of Canyon's 292 bridges with a recorded construction year (99%), against a county median build year of 1983. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

SMA 7733;KIMBALL A 37.2 t
Idaho average (4,574 of 4,616 rated) 33.3 t

Live comparison across Idaho bridges with a recorded inventory load rating (4,574 of 4,616 rated).

SMA 7733;KIMBALL A vs every rated Idaho bridge

Inventory load rating (metric tons), FHWA NBI, this state

37 Top 32% higher than 68% of 4,574 bridges

rated Idaho bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
37.2 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Canyon inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 292 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1933
Last Reconstructed
2008
Material
Concrete
Number of Spans
2
Structure Length
11.9 m (39 ft)
Deck Width
41.9 m (137 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
3,500 vehicles/day
Structure Number
000000000027610

Condition Analysis

  • At 5/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, with advanced deterioration recorded on the latest inspection.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

SMA 7733;KIMBALL A is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare SMA 7733;KIMBALL A against other structures in Canyon and across Idaho. Idaho bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SMA 7733;KIMBALL A?

SMA 7733;KIMBALL A in Canyon, Idaho has a deck rating of 5/9, superstructure rating of 4/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is SMA 7733;KIMBALL A inspected?

SMA 7733;KIMBALL A's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 3,500 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SMA 7733;KIMBALL A is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SMA 7733;KIMBALL A?

SMA 7733;KIMBALL A has an NBI inventory load rating of 37.2 metric tons.

Who is responsible for maintaining SMA 7733;KIMBALL A?

SMA 7733;KIMBALL A is owned and maintained by City/Municipal Highway Agency.

How old is SMA 7733;KIMBALL A and does age affect safety?

SMA 7733;KIMBALL A was built in 1933, making it 93 years old and last reconstructed in 2008.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.