FHWA NBI 2024 Inspection record Public-domain dataset

FAU 7123(IL 10)

Carrying FAU 7123(IL 10) over COPPER SLOUGH

W EDGE OF CHAMPAIGN, Champaign, Illinois

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
26 t Inventory load rating Lower than 86% of rated Illinois bridges

FAU 7123(IL 10) in Champaign, Illinois sits above 14% of rated Illinois bridges on inventory load rating (26 t), while its 1940 build year is earlier than 96% of Champaign's recorded-year cohort (727 bridges).

FAU 7123(IL 10) in Champaign, Illinois is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1940, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure IL:010013500000000

PRE-1950 · CONCRETE · SINGLE-SPAN · SUPER-LED · HEAVY-ADT · STANDARD-LOAD · CAT-POOR

  • PRE-1950 Pre-1950
  • CONCRETE Concrete
  • SINGLE-SPAN Single span
  • SUPER-LED Superstructure-led
  • HEAVY-ADT Heavy ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: FAU 7123(IL 10)

The FAU 7123(IL 10) bridge in Champaign, Illinois carries FAU 7123(IL 10) over COPPER SLOUGH. It was built in 1940, making it 86 years old today. The structure is built primarily of concrete and spans 1 section, stretching 11.0 meters (36 feet) end to end. Daily traffic averages 12,100 vehicles, placing it in the heavily-trafficked tier of Illinois bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 4/9, substructure at 6/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed.

How FAU 7123(IL 10) compares

▼ 9.4
Load rating vs Illinois average (35.0 t; 26,904 of 26,928 rated)
727
Bridges in Champaign · 63 in Poor condition

Age against the county: built in 1940, earlier than 695 of Champaign's 727 bridges with a recorded construction year (96%), against a county median build year of 1983. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

FAU 7123(IL 10) 25.6 t
Illinois average (26,904 of 26,928 rated) 35.0 t

Live comparison across Illinois bridges with a recorded inventory load rating (26,904 of 26,928 rated).

FAU 7123(IL 10) vs every rated Illinois bridge

Inventory load rating (metric tons), FHWA NBI, this state

26 Top 86% higher than 14% of 26,904 bridges

rated Illinois bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
25.6 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Champaign inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 727 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1940
Material
Concrete
Number of Spans
1
Structure Length
11.0 m (36 ft)
Deck Width
13.2 m (43 ft)
Owner
State Highway Agency
Avg Daily Traffic
12,100 vehicles/day
Structure Number
010013500000000

Condition Analysis

  • The deck (driving surface) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) is in poor condition (4/9), showing advanced deterioration on the inspecting agency's 0-9 scale.
  • At 6/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

FAU 7123(IL 10) is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare FAU 7123(IL 10) against other structures in Champaign and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for FAU 7123(IL 10)?

FAU 7123(IL 10) in Champaign, Illinois has a deck rating of 5/9, superstructure rating of 4/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is FAU 7123(IL 10) inspected?

FAU 7123(IL 10)'s responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 12,100 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. FAU 7123(IL 10) is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for FAU 7123(IL 10)?

FAU 7123(IL 10) has an NBI inventory load rating of 25.6 metric tons.

Who is responsible for maintaining FAU 7123(IL 10)?

FAU 7123(IL 10) is owned and maintained by State Highway Agency.

How old is FAU 7123(IL 10) and does age affect safety?

FAU 7123(IL 10) was built in 1940, making it 86 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.