FHWA NBI 2024 Inspection record Public-domain dataset

FAU 7200(PERKINS R

Carrying FAU 7200(PERKINS R over SALINE BRANCH DITCH

NE EDGE OF URBANA, Champaign, Illinois

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
26 t Inventory load rating Lower than 86% of rated Illinois bridges

FAU 7200(PERKINS R in Champaign, Illinois sits above 14% of rated Illinois bridges on inventory load rating (26 t), while its 1977 build year is earlier than 64% of Champaign's recorded-year cohort (727 bridges).

FAU 7200(PERKINS R in Champaign, Illinois is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1977, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure IL:010409900000000

INTERSTATE-ERA · PRESTRESS · MULTI-SPAN · TIED-CTRL · ARTERIAL-ADT · STANDARD-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • PRESTRESS Prestressed concrete
  • MULTI-SPAN 3 spans
  • TIED-CTRL Tied control
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: FAU 7200(PERKINS R

The FAU 7200(PERKINS R bridge in Champaign, Illinois carries FAU 7200(PERKINS R over SALINE BRANCH DITCH. It was built in 1977, making it 49 years old today. The structure is built primarily of prestressed concrete and spans 3 sections, stretching 46.1 meters (151 feet) end to end. Daily traffic averages 1,450 vehicles, placing it in the moderately-trafficked tier of Illinois bridges. It is owned and maintained by Town/Township Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 4/9, substructure at 7/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed.

How FAU 7200(PERKINS R compares

▼ 9.1
Load rating vs Illinois average (35.0 t; 26,904 of 26,928 rated)
727
Bridges in Champaign · 63 in Poor condition

Age against the county: built in 1977, earlier than 467 of Champaign's 727 bridges with a recorded construction year (64%), against a county median build year of 1983. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

FAU 7200(PERKINS R 25.9 t
Illinois average (26,904 of 26,928 rated) 35.0 t

Live comparison across Illinois bridges with a recorded inventory load rating (26,904 of 26,928 rated).

FAU 7200(PERKINS R vs every rated Illinois bridge

Inventory load rating (metric tons), FHWA NBI, this state

26 Top 86% higher than 14% of 26,904 bridges

rated Illinois bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
4/9
Poor (1–4)
Substructure
7/9
Good (7–9)
Inventory Load Rating
25.9 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Champaign inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 727 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1977
Material
Prestressed Concrete
Number of Spans
3
Structure Length
46.1 m (151 ft)
Deck Width
8.5 m (28 ft)
Owner
Town/Township Highway Agency
Avg Daily Traffic
1,450 vehicles/day
Structure Number
010409900000000

Condition Analysis

  • The deck (driving surface) is in poor condition (4/9), showing advanced deterioration on the inspecting agency's 0-9 scale.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, with advanced deterioration recorded on the latest inspection.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

FAU 7200(PERKINS R is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare FAU 7200(PERKINS R against other structures in Champaign and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for FAU 7200(PERKINS R?

FAU 7200(PERKINS R in Champaign, Illinois has a deck rating of 4/9, superstructure rating of 4/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is FAU 7200(PERKINS R inspected?

FAU 7200(PERKINS R's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,450 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. FAU 7200(PERKINS R is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for FAU 7200(PERKINS R?

FAU 7200(PERKINS R has an NBI inventory load rating of 25.9 metric tons.

Who is responsible for maintaining FAU 7200(PERKINS R?

FAU 7200(PERKINS R is owned and maintained by Town/Township Highway Agency.

How old is FAU 7200(PERKINS R and does age affect safety?

FAU 7200(PERKINS R was built in 1977, making it 49 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.